ABB A44 112-100
CT/VT-connected DIN energy metering with RS-485: select the Steel variant, set transformer ratios and verify a literal-address voltage read.
- Energy meters
Meters, sensors and controllers, and how each connects to Edge.
279 device pages · 84 manufacturers with device pages
283 devices
CT/VT-connected DIN energy metering with RS-485: select the Steel variant, set transformer ratios and verify a literal-address voltage read.
D11 and D13 are direct-connected DIN-rail meters with different phase and current ratings. Their Modbus variants share an integer register map with four-register energy counters and explicit invalid-value markers.
Panel energy monitoring with conventional CTs, two digital outputs and RS-485: exact M4M20RS485 setup and a scaled-integer Modbus read.
M4M 30 Modbus is a panel network analyser for conventional 1 A or 5 A CTs, with RS-485, Bluetooth commissioning and four programmable I/O. Edge reads its scaled electrical values over Modbus RTU.
Monitor LINAX PQ5000 over Modbus TCP with a first frequency read, documented float decoding and local-interface checks.
Read the EM24-DIN RS-485 meter with Edge: distinguish direct and CT inputs, import the 32-point map and verify signed, word-swapped measurements.
Single-phase direct-connected Modbus meter with a low-word-first integer read and a 32 A connection boundary.
Direct-connected 65 A three-phase energy metering with RS-485: exact S1 X setup, bidirectional measurement and a low-word-first register check.
Compare the 5 A CT-input EM530 with the direct-connected 65 A EM540, then configure RS-485, integer scaling and a read-only voltage check.
Monitor Cat EMCP 4.3 and 4.4 generator set controllers over the documented customer Modbus interface while keeping engine, breaker and paralleling control separate.
Connect InteliGen 200 monitoring over Modbus RTU or TCP using OEM interface documentation.
Monitor an InteliGen 500 G2 over its documented Modbus RTU or TCP interface while leaving generator, breaker, synchronising and load-share control with the commissioned ComAp system.
Connect InteliLite 4 AMF 20 monitoring over Modbus RTU or TCP using OEM interface documentation.
Connect InteliLite 4 AMF 25 monitoring over Modbus RTU or TCP using OEM interface documentation.
Connect InteliMains 210 monitoring over Modbus RTU or TCP using OEM interface documentation.
Connect InteliMains NT monitoring over Modbus RTU using OEM interface documentation.
Monitor a CRE Technology GENSYS COMPACT PRIME through its documented Modbus TCP server while keeping generator, breaker and power-control writes disabled.
Assess a Cummins PowerCommand 3.3 generator set controller for external monitoring while keeping the exact controller revision, Modbus data contract and every operational command outside the assumed scope.
Floor-standing E7 indoor heat-pump unit with an integrated 180 litre hot-water tank, paired here with the EPRA14DV37 outdoor unit.
Connect DSE7320 MKII monitoring over Modbus RTU using OEM interface documentation.
Connect DSE8610 MKII monitoring over Modbus RTU or TCP using OEM interface documentation.
Monitor a DSE8620 MKII through its documented Modbus RTU or Modbus TCP interface while keeping generator, breaker and load-share control with the commissioned control system.
Monitor a DEIF AGC 150 Stand-alone generator controller through its documented Modbus server while keeping start, stop and breaker operation outside the Edge client.
A 29.9 to 50 kW three-phase hybrid-inverter family combining PV, high-voltage batteries, grid, load and optional generator operation.
No devices match your filters
Try a broader model fragment, manufacturer or application.
Built from public Zigbee, LoRaWAN and Modbus device definitions and manufacturer documents, including BACnet/IP guides. Exact manufacturer and model identities are joined; similar names are never assumed to be the same device.
Each device page explains the documented connection to Edge, what the device reports and how to check its setup. An Edge template is offered only where an exact reviewed import is available.
Every page cites its sources. Zigbee device photographs come from the Zigbee2MQTT project and are credited under each photograph. We never run code from these sources, and register maps are for reading: never write to a meter from a map on this site.
Tell us the manufacturer and model, and we'll look at its documentation.