Huawei LUNA2000-241-2S1
Assess the Huawei LUNA2000-241-2S1 C&I ESS for read-only monitoring, with Modbus TCP, controller, safety and measurement boundaries.
- Battery systems and controls
Meters, sensors and controllers, and how each connects to Edge.
279 device pages · 84 manufacturers with device pages
283 devices
Assess the Huawei LUNA2000-241-2S1 C&I ESS for read-only monitoring, with Modbus TCP, controller, safety and measurement boundaries.
Assess the Huawei SmartLogger3000A as a PV and energy-storage plant data logger while keeping its exact A00, A01 or A03 variant and third-party interface boundary explicit.
Single-phase 2 to 6 kW PV inverter family with two MPP trackers, a battery port and separate cascade and meter/battery RS485 terminal roles.
Three-phase high-current PV inverter family rated from 3 to 10 kW, with two MPP trackers, a battery port and distinct plant and meter/battery RS485 roles.
Five three-phase PV inverter ratings from 12 to 25 kW, with two MPP trackers and distinct RS485 wiring for the plant logger and power meter.
Assess the current INTILION scalepac C&I battery system for operational monitoring, with configuration, interface and control boundaries.
A 96 mm panel analyser with external CT inputs, local recording and optional expansion. Start with its native RS-485 interface and distinguish standard models from the separately identified Class S variants.
Connect a Janitza UMG 96RM-E to Edge over Modbus: verify CT inputs, TCP versus RTU framing, float decoding and transformer scaling.
UMG 103-CBM adds a clock and local measurement storage to compact DIN-rail monitoring. Its firmware-scoped Modbus list offers both byte-order address spaces, so choose the documented bank before decoding a value.
Panel power analyser with a manufacturer FC03 voltage telegram and a separate Modbus address list.
A power-quality analyser with Class A measurement functions, waveform-related recording and network interfaces. Keep routine Modbus readings separate from event records and standards-based PQ analysis.
A DIN-rail analyser with four voltage and current inputs, Ethernet and configurable serial roles. Read its own measurements without confusing a Modbus server with a downstream gateway.
DIN-rail power-quality analyser with an RS-485 Modbus server and a firmware-scoped measurement map.
The blueplanet 92.0, 105 and 125 TL3 are 1500 V commercial string inverters with one MPP tracker.
R32 monobloc heat pump paired with FTC6 PAC-IF072B-E, with best-effort temperature monitoring through a separately fitted MelcoBEMS MINI A1M+.
Read TriStar MPPT 60 battery and array measurements over Ethernet, using the controller’s own voltage and current scaling registers.
An inverter-controlled S-Series ground-source heat pump with an integrated water heater and built-in Modbus TCP/IP on supported software.
Read Nuvation G5 battery-stack status through SunSpec Modbus TCP while preserving the existing battery controller’s connection and safety responsibilities.
Nine-kilowatt K-generation split heat-pump kit comprising WH-SDC0309K3E5 indoor and WH-UDZ09KE5 outdoor units.
Read EEM-MA370 frequency, current, voltage and power over Modbus TCP, with documented addresses and a first-read decoding example.
Assess the Pixii PowerShaper XL 60 kW / 225 kWh LFP system for commercial energy storage, with exact capacity, interface and control-evidence boundaries.
CT-connected DIN meter with local RS-485, digital I/O and a model-specific PM3200 Modbus register table.
Panel power meters for 1 A or 5 A current transformers, with Modbus RTU on RS-485 or Modbus TCP on Ethernet. Edge reads them through a Modbus interface, the Gateway’s serial port or the site network.
The PM5560 is a panel meter for 1 A or 5 A current transformers, with RS-485 and two Ethernet ports. Read its own electrical measurements over Modbus, while keeping downstream serial meters separate from the PM5560 endpoint.
No devices match your filters
Try a broader model fragment, manufacturer or application.
Built from public Zigbee, LoRaWAN and Modbus device definitions and manufacturer documents, including BACnet/IP guides. Exact manufacturer and model identities are joined; similar names are never assumed to be the same device.
Each device page explains the documented connection to Edge, what the device reports and how to check its setup. An Edge template is offered only where an exact reviewed import is available.
Every page cites its sources. Zigbee device photographs come from the Zigbee2MQTT project and are credited under each photograph. We never run code from these sources, and register maps are for reading: never write to a meter from a map on this site.