Danfoss AK-CC55
Display case and cold room controller with built-in Modbus RTU on RS-485. Danfoss publishes a basic Modbus parameter list for each of the Compact, Single Coil and Multi Coil.
- Refrigeration controllers
Meters, sensors and controllers, and how each connects to Edge.
394 device pages · 121 manufacturers with device pages
398 devices
Display case and cold room controller with built-in Modbus RTU on RS-485. Danfoss publishes a basic Modbus parameter list for each of the Compact, Single Coil and Multi Coil.
Cabinet and cold room controller that answers Modbus RTU on RS-485 through the EKA 178A module. Danfoss publishes a parameter number for every temperature, relay and alarm.
Compact refrigeration controller for plug-in cabinets and small cold rooms. Danfoss publishes Modbus parameter numbers for its TTL programming port, which a ZMB-31 reads through a TTL to RS-485 interface.
Connect DSE7320 MKII monitoring over Modbus RTU using OEM interface documentation.
Connect DSE8610 MKII monitoring over Modbus RTU or TCP using OEM interface documentation.
Monitor a DSE8620 MKII through its documented Modbus RTU or Modbus TCP interface while keeping generator, breaker and load-share control with the commissioned control system.
Monitor a DEIF AGC 150 Stand-alone generator controller through its documented Modbus server while keeping start, stop and breaker operation outside the Edge client.
Three-channel networked submeter from DENT Instruments for 333 mV or RōCoil CTs, with Modbus RTU or BACnet MS/TP on RS-485 and, on the PS3037-E, Modbus TCP or BACnet/IP on Ethernet.
Networked multi-circuit power meters from DENT Instruments with 3, 12, 24 or 48 CT channels, with Modbus RTU or BACnet MS/TP on RS-485 and Modbus TCP or BACnet/IP on Ethernet.
A 200 kW, 430.08 kWh liquid-cooled LFP cabinet with two 100 kW PCS modules, battery management and fire suppression for commercial and industrial sites.
A 250 kW, 522.496 kWh liquid-cooled LFP cabinet for commercial and industrial sites, with its PCS, battery, cooling and fire suppression in one enclosure.
A 200 kW, 482.304 kWh liquid-cooled LFP cabinet that stores PV and grid energy for DC fast charging at commercial charging sites.
A 29.9 to 50 kW three-phase hybrid-inverter family combining PV, high-voltage batteries, grid, load and optional generator operation.
A 100 to 125 kW three-phase hybrid inverter family for high-voltage batteries, with eight or ten MPPTs, generator input and up to ten units in parallel.
Read thermal energy, power, flow and temperature from a SHARKY 775 fitted with Diehl's Modbus RTU module. Includes a documented first energy read.
32 x 74 mm panel controller for medium and low temperature ventilated units, with compressor, defrost and fan relays. Its TTL serial line on the HOT KEY connector reaches Modbus RTU through Dixell's XJ485-CX converter.
32 x 74 mm panel controller for low temperature ventilated units, with compressor, defrost, fan and configurable light relays, an optional real time clock and built-in RS485 for Modbus RTU.
32 x 74 mm panel controller for medium and low temperature units with compressor, defrost, fan and alarm or auxiliary relays, a door switch input and built-in RS485 for Modbus RTU.
Single-phase one-module DIN-rail meter for 1 A or 5 A CTs, with an RS-485 Modbus RTU port, two pulse outputs and separate import and export energy registers.
SDM230-Modbus is a two-module, single-phase meter for direct connection up to 100 A. Read import and export energy separately, match the installed serial settings and decode complete float32 register pairs.
Direct-connected three-phase meter up to 100 A with an RS-485 Modbus RTU port. Edge reads it through a Modbus interface or the Gateway’s serial port.
A direct-connected 100 A energy meter with native Ethernet. Set its network address, read complete float measurements and compare them with the display.
A DIN-rail energy meter for external 1 A or 5 A current transformers. Configure the CT secondary and ratio on the meter, then read complete float32 measurements over RS-485 Modbus RTU.
Panel power meter and DIN-rail transducer from Electro Industries/GaugeTech for 5 A or 1 A CTs, with an RS-485 Modbus RTU port on the 485P option and an optional INP10 Ethernet card.
No devices match your filters
Try a broader model fragment, manufacturer or application.
Built from public Zigbee, LoRaWAN and Modbus device definitions and manufacturer documents, including BACnet/IP guides. Exact manufacturer and model identities are joined; similar names are never assumed to be the same device.
Each device page explains the documented connection to Edge, what the device reports and how to check its setup. An Edge template is offered only where an exact reviewed import is available.
Every page cites its sources. Zigbee device photographs come from the Zigbee2MQTT project and are credited under each photograph. We never run code from these sources, and register maps are for reading: never write to a meter from a map on this site.
Tell us the manufacturer and model, and we'll look at its documentation.