GoodWe SMT 50–60 kW
Compare the GoodWe SMT 50 and 60 kW EMEA inverters, including -EU grid-code variants, RS485 wiring and monitoring prerequisites.
- Inverters and charge controllers
Meters, sensors and controllers, and how each connects to Edge.
17 device pages · 84 manufacturers with device pages
17 devices
Compare the GoodWe SMT 50 and 60 kW EMEA inverters, including -EU grid-code variants, RS485 wiring and monitoring prerequisites.
Read Sungrow SH20T identity, battery SOC and active power over WiNet-S2 Modbus TCP, using the published hybrid map and clear meter boundaries.
Compare original Battery-Box Premium HVS and HVM capacity, inverter compatibility and inverter-mediated monitoring.
Five exact SDT G3 model codes at 8, 10, 12 and 15 kW, with two PV trackers, separate inverter-network and meter RS485 terminals, and optional communication sticks.
A commercial string-inverter family spanning 100 to 150 kW across distinct low-voltage and medium-voltage variants.
Three-phase 11 to 30 kW battery-ready PV inverter family with two or three MPPTs and separate parallel, meter, battery and backup communication connections.
A 2.5 to 6 kW single-phase battery-ready inverter family with separate RJ45 ports for the meter, third-party monitoring and a VPP protocol.
Three-phase battery-ready inverter family with two PV inputs and distinct parallel, meter, battery and SYN communication terminals.
Three-phase 4 to 25 kW hybrid inverter family for high-voltage batteries, with a generator input, backup output and dedicated meter, monitoring and EMS/VPP communication roles.
100 kW commercial string inverter with ten MPP trackers and separate inverter, logger and grid-meter communication roles.
Plan monitoring for the Huawei SUN2000-150K-MG0 by checking its seven-MPPT design, regional hardware, logger network and grid-meter port.
Choose the exact 14-S1 battery build, its inverter and firmware compatibility, and its inverter-owned communication path.
A manufacturer-independent PV plant data logger for installations up to 2 MWp, with inverter, meter, portal and optional power-management functions.
Size the CSS-OD 197 cabinet and its one or two PCS050 battery inverters using the manufacturer’s usable-energy, power and country limits.
Sungrow SG320HX-20 selection guide covering its six MPPT inputs, temperature-dependent AC rating, RS485 monitoring and Sungrow PLC logger topology.
SG350HX-20 utility PV inverter selection guide covering the six-MPPT array, temperature-rated AC output and the documented RS485 or PLC-to-logger monitoring paths.
Assess the exact WAGO PFC200 BACnet/IP variant for external monitoring while keeping its IEC 61131 application, I/O and control authority inside the commissioned PLC project.
No devices match your filters
Try a broader model fragment, manufacturer or application.
Built from public Zigbee, LoRaWAN and Modbus device definitions and manufacturer documents, including BACnet/IP guides. Exact manufacturer and model identities are joined; similar names are never assumed to be the same device.
Each device page explains the documented connection to Edge, what the device reports and how to check its setup. An Edge template is offered only where an exact reviewed import is available.
Every page cites its sources. Zigbee device photographs come from the Zigbee2MQTT project and are credited under each photograph. We never run code from these sources, and register maps are for reading: never write to a meter from a map on this site.
Tell us the manufacturer and model, and we'll look at its documentation.