Solis S6-EH3P50K-H
Monitor the European Solis S6-EH3P50K-H through its EMS interface or supported logger, using public Modbus frequency, battery SOC and PV power registers.
- Inverters and charge controllers
Meters, sensors and controllers, and how each connects to Edge.
279 device pages · 84 manufacturers with device pages
283 devices
Monitor the European Solis S6-EH3P50K-H through its EMS interface or supported logger, using public Modbus frequency, battery SOC and PV power registers.
Monitor WPL 25 AC through its WPM and a compatible ISG: Modbus TCP setup, temperature register candidates and independent heat/electricity metering.
A 15, 17 and 20 kW three-phase PV inverter family with two MPPTs, a COM2 RS-485 daisy-chain connection and separate meter terminals.
The original SG110CX has nine MPPTs and two strings per MPPT.
A 125 kW three-phase string inverter with twelve MPPTs and a documented RS485_1 monitoring interface.
A 150 kW three-phase string inverter with seven MPPTs and a documented RS485_1 monitoring terminal.
Identify the original SH10RT and read its PV, battery and meter measurements through the documented local Modbus path.
Read Sungrow SH20T identity, battery SOC and active power over WiNet-S2 Modbus TCP, using the published hybrid map and clear meter boundaries.
Read battery, inverter/charger and solar-charger data through the Cerbo GX MK2 local Modbus TCP gateway.
Connect easYgen-2500 monitoring over Modbus RTU using OEM interface documentation.
Connect easYgen-3200XT monitoring over Modbus RTU or TCP using OEM interface documentation.
Monitor a Woodward easYgen-3500XT over its documented Modbus TCP or Modbus RTU slave interface while keeping generator, breaker, synchronising and load-share control outside Edge.
Self-powered single-phase LoRaWAN current transformers. Edge reads their decoded uplinks from your LoRaWAN network server.
Self-powered three-phase LoRaWAN current transformers with three split-core clamps. Edge reads their decoded uplinks from your LoRaWAN network server.
Monitor Terra 360 CC through the commissioned charging backend, with dual-CCS2 power sharing, electrical limits and site-meter comparison.
Select the three-phase Type 2 socket variant 904460023 and separate its certified OCPP backend from direct Edge integration.
Select and commission the European HYC400 Series 2 without treating its OCPP central-system link as a direct Edge integration.
Compare original Battery-Box Premium HVS and HVM capacity, inverter compatibility and inverter-mediated monitoring.
Plan monitoring for InteliLite NT AMF 25 with its documented interfaces and electrical measurements.
Plan monitoring for DSE4520 MKII with its documented interfaces and electrical measurements.
Plan monitoring for DSE6120 MKIII with its documented interfaces and electrical measurements.
Commission the exact 22 kW, six-metre tethered Wattpilot Flex Home C6 and verify its OCPP 1.6 J management connection without assuming direct Edge control.
Five exact SDT G3 model codes at 8, 10, 12 and 15 kW, with two PV trackers, separate inverter-network and meter RS485 terminals, and optional communication sticks.
A commercial string-inverter family spanning 100 to 150 kW across distinct low-voltage and medium-voltage variants.
No devices match your filters
Try a broader model fragment, manufacturer or application.
Built from public Zigbee, LoRaWAN and Modbus device definitions and manufacturer documents, including BACnet/IP guides. Exact manufacturer and model identities are joined; similar names are never assumed to be the same device.
Each device page explains the documented connection to Edge, what the device reports and how to check its setup. An Edge template is offered only where an exact reviewed import is available.
Every page cites its sources. Zigbee device photographs come from the Zigbee2MQTT project and are credited under each photograph. We never run code from these sources, and register maps are for reading: never write to a meter from a map on this site.
Tell us the manufacturer and model, and we'll look at its documentation.