Growatt MID 36-60KTL3-X3
Three-phase 36 to 60 kW PV inverter family with four or five MPPTs and separate RS-485 connections for inverter monitoring and a commissioned meter.
- Inverters and charge controllers
Meters, sensors and controllers, and how each connects to Edge.
394 device pages · 121 manufacturers with device pages
398 devices
Three-phase 36 to 60 kW PV inverter family with four or five MPPTs and separate RS-485 connections for inverter monitoring and a commissioned meter.
Direct-connected 80 A single-phase MID meter in two DIN modules, with a three-wire RS-485 Modbus RTU port and a published, revisioned register table.
Monitor a Hager ECR300C CT-connected three-phase meter through its documented Modbus RTU interface while preserving the separate rules for MID billing data.
Direct-connected 80 A three-phase MID meter with a three-wire RS-485 Modbus RTU port and a published, revisioned register table.
Three-phase DIN-rail power sensor that Huawei supplies with its FusionSolar inverters for export limitation and battery control, with RS-485 Modbus RTU and no published register map.
Read Huawei LUNA2000-200KWH-2H1 SOC, power and energy over Modbus TCP from its CMU with the LUNA2000B port definitions, or through a SmartLogger3000.
Read Huawei LUNA2000-215-2S10 SOC, power and capacity over Modbus TCP through the SmartLogger3000 that manages it, with SmartLogger issue 43 ESS registers.
Assess the Huawei LUNA2000-241-2S1 C&I ESS for read-only monitoring, with Modbus TCP, controller, safety and measurement boundaries.
Assess the Huawei SmartLogger3000A as a PV and energy-storage plant data logger while keeping its exact A00, A01 or A03 variant and third-party interface boundary explicit.
Single-phase 2 to 6 kW PV inverter family with two MPP trackers, a battery port and separate cascade and meter/battery RS485 terminal roles.
Three-phase high-current PV inverter family rated from 3 to 10 kW, with two MPP trackers, a battery port and distinct plant and meter/battery RS485 roles.
Five three-phase PV inverter ratings from 12 to 25 kW, with two MPP trackers and distinct RS485 wiring for the plant logger and power meter.
Single-phase 45 A DIN-rail meter with RS-485 Modbus RTU, a hexadecimal FC03 register map and Float32 values sent high word first.
Three-phase DIN-rail meter with RS-485 Modbus RTU, a hexadecimal FC03 register map and Float32 values sent high word first.
Read the INGECON SUN STORAGE 1Play 3TL M, 4.5TL M and 6TL M over Modbus TCP: battery, PV, grid and AC load values from Ingeteam's input-register map.
Read the INGECON SUN STORAGE 100TL battery inverter over Modbus TCP: AC power, DC power, battery state of charge, status and alarms from Ingeteam's input-register map.
Assess the current INTILION scalepac C&I battery system for operational monitoring, with configuration, interface and control boundaries.
96 mm panel power monitoring devices from Iskra: the MC 740 multifunction meter, MC 750 network recorder and MC 770 power quality analyser, with Modbus RTU on RS485 and Modbus TCP on the Ethernet option.
Three-phase 40 A direct-connected MID meter with RS-485 Modbus RTU, a published input register table and Iskra's own exponent-and-value data types.
A 96 × 96 mm panel power analyser with external CT inputs and an RS-485 Modbus RTU port. Janitza publishes a Float measurement table from decimal address 19000, read high byte first.
A 96 mm panel analyser with external CT inputs, local recording and optional expansion. Start with its native RS-485 interface and distinguish standard models from the separately identified Class S variants.
A 96 × 96 mm panel energy analyser with external CT inputs and an RS-485 Modbus RTU port. Janitza publishes a Float measurement table from decimal address 19000, read high byte first.
Connect a Janitza UMG 96RM-E to Edge over Modbus: verify CT inputs, TCP versus RTU framing, float decoding and transformer scaling.
UMG 103-CBM adds a clock and local measurement storage to compact DIN-rail monitoring. Its firmware-scoped Modbus list offers both byte-order address spaces, so choose the documented bank before decoding a value.
No devices match your filters
Try a broader model fragment, manufacturer or application.
Built from public Zigbee, LoRaWAN and Modbus device definitions and manufacturer documents, including BACnet/IP guides. Exact manufacturer and model identities are joined; similar names are never assumed to be the same device.
Each device page explains the documented connection to Edge, what the device reports and how to check its setup. An Edge template is offered only where an exact reviewed import is available.
Every page cites its sources. Zigbee device photographs come from the Zigbee2MQTT project and are credited under each photograph. We never run code from these sources, and register maps are for reading: never write to a meter from a map on this site.
Tell us the manufacturer and model, and we'll look at its documentation.