WAGO PFC200 BACnet/IP
Assess the exact WAGO PFC200 BACnet/IP variant for external monitoring while keeping its IEC 61131 application, I/O and control authority inside the commissioned PLC project.
- Integration controllers
Meters, sensors and controllers, and how each connects to Edge.
394 device pages · 121 manufacturers with device pages
398 devices
Assess the exact WAGO PFC200 BACnet/IP variant for external monitoring while keeping its IEC 61131 application, I/O and control authority inside the commissioned PLC project.
ABB's MID-approved three-phase DIN-rail energy meters: the B23 connects directly up to 65 A and the B24 reads current transformers with a secondary of up to 6 A. Edge reads it through a Modbus interface or the Gateway’s serial port.
ABB's 96 × 96 mm panel network analysers for 1 A or 5 A current transformers, with Class 0.5S active energy, harmonics to the 40th and a colour display. Edge reads it through a Modbus interface or the Gateway’s serial port.
Two three-phase DIN-rail energy meters on one register map: the EM340 connects directly up to 65 A and powers itself, the EM330 reads 5 A current transformers. Edge reads it through a Modbus interface, the Gateway’s serial port or the site network.
A single-phase energy transducer with no display, two DIN modules wide, for direct connection up to 100 A. Edge reads it through a Modbus interface or the Gateway’s serial port.
A three-phase, four-wire DIN-rail energy meter that reads current transformers, with Class 1 active energy, per-phase import and export counters and an RS-485 Modbus RTU port, in a 72 mm housing. Edge reads it through a Modbus interface or the Gateway’s serial port.
A three-phase, four-wire DIN-rail energy meter for direct connection up to 100 A, with import and export energy, resettable counters and an RS-485 Modbus RTU port, in a 72 mm housing that needs no auxiliary supply. Edge reads it through a Modbus interface or the Gateway’s serial port.
A single-phase DIN-rail meter for direct connection up to 45 A, with separate import and export energy counters and an RS-485 Modbus RTU port. Edge reads it through a Modbus interface or the Gateway’s serial port.
Two single-phase DIN-rail energy meters, two modules wide, for direct connection up to 100 A, with import and export energy, demand values and an RS-485 Modbus RTU port on one shared register map. Edge reads it through a Modbus interface or the Gateway’s serial port.
A 4-module DIN-rail power analyser that runs from the voltage it measures and reads 1 A or 5 A current transformers, with Class 0.5S energy on 5 A CTs and harmonics to the 25th. Edge reads it through a Modbus interface or the Gateway’s serial port.
Schneider Electric DIN-rail meters with RS-485 Modbus RTU: iEM3150 and iEM3155 measure directly up to 63 A, iEM3350 and iEM3355 up to 125 A, and iEM3250 and iEM3255 use 1 A or 5 A CTs. Edge reads it through a Modbus interface or the Gateway’s serial port.
A 96 × 96 mm panel meter for low-voltage distribution, on 1 A or 5 A current transformers, with Class 0.5S active energy and more than 50 measured values. Edge reads it through a Modbus interface or the Gateway’s serial port.
A 96 × 96 mm panel meter with a touchscreen that measures energy, power and power quality through Socomec's own plug-in current sensors, which it recognises by type and rating. Edge reads it through a Modbus interface, the Gateway’s serial port or the site network.
A battery-powered LoRaWAN pulse counter for water, gas, electricity and heat meters. Edge reads its decoded uplinks from your LoRaWAN network server.
A battery-powered LoRaWAN room sensor for CO₂, total VOC, temperature, humidity, air pressure, light and motion, sampling every 30 seconds and sending the averages every 10 minutes. Edge reads its decoded uplinks from your LoRaWAN network server.
A battery-powered LoRaWAN temperature and humidity sensor with a connector for an external probe, reporting every 20 minutes by default and logging up to 3,328 readings when the network is down. Edge reads its decoded uplinks from your LoRaWAN network server.
A wall-mounted LoRaWAN room sensor that measures CO₂, temperature, humidity, light and motion, runs on one or two AA lithium cells and is configured by NFC from a phone. Edge reads its decoded uplinks from your LoRaWAN network server.
A wall-mounted LoRaWAN room sensor with an E-ink screen that measures CO₂, temperature, humidity, TVOC, barometric pressure, light and occupancy. Edge reads its decoded uplinks from your LoRaWAN network server.
A mains-powered LoRaWAN room monitor with an E-ink screen that measures CO₂, PM2.5, PM10, TVOC, formaldehyde or ozone, temperature, humidity, pressure, light and occupancy. Edge reads its decoded uplinks from your LoRaWAN network server.
A battery-powered LoRaWAN pulse counter for water, gas and energy meters with a reed switch or passive pulse output. Edge reads its decoded uplinks from your LoRaWAN network server.
A battery-powered LoRaWAN temperature and humidity sensor in an IP67 enclosure, rated for -30 to 70 °C, reporting every 10 minutes by default on a 4000 mAh cell. Edge reads its decoded uplinks from your LoRaWAN network server.
A LoRaWAN transmitter with a 3-wire PT100 probe for pipes, plant, ovens and cold processes. Edge reads its decoded uplinks from your LoRaWAN network server.
A DIN-rail LoRaWAN controller with four digital or pulse inputs, two relay outputs, two 4-20 mA and two 0-10 V inputs, two PT100 inputs and an RS-485 port that polls up to 32 Modbus RTU registers. Edge reads its decoded uplinks from your LoRaWAN network server.
A coin-cell LoRaWAN leak sensor for floors, plant rooms and risers. Edge reads its decoded uplinks from your LoRaWAN network server.
No devices match your filters
Try a broader model fragment, manufacturer or application.
Built from public Zigbee, LoRaWAN and Modbus device definitions and manufacturer documents, including BACnet/IP guides. Exact manufacturer and model identities are joined; similar names are never assumed to be the same device.
Each device page explains the documented connection to Edge, what the device reports and how to check its setup. An Edge template is offered only where an exact reviewed import is available.
Every page cites its sources. Zigbee device photographs come from the Zigbee2MQTT project and are credited under each photograph. We never run code from these sources, and register maps are for reading: never write to a meter from a map on this site.
Tell us the manufacturer and model, and we'll look at its documentation.