Huawei SUN2000-100KTL-M2
100 kW commercial string inverter with ten MPP trackers and separate inverter, logger and grid-meter communication roles.
- Inverters and charge controllers
Meters, sensors and controllers, and how each connects to Edge.
394 device pages · 121 manufacturers with device pages
398 devices
100 kW commercial string inverter with ten MPP trackers and separate inverter, logger and grid-meter communication roles.
Plan monitoring for the Huawei SUN2000-150K-MG0 by checking its seven-MPPT design, regional hardware, logger network and grid-meter port.
Choose the exact 14-S1 battery build, its inverter and firmware compatibility, and its inverter-owned communication path.
A residential AC wall charger with a Type 2 socket and up to 22 kW three-phase output. Huawei lists Modbus TCP and OCPP 1.6, but limits OCPP to residential use without commercial billing. Check the installed firmware and system controller before planning solar-surplus charging or an external monitoring connection.
Plan the modular Station Charger Version 2, its C500 or C800 modules and its third-party backend boundary.
Monitor Pylontech US5000 SOC, voltage and current through a Victron GX device: CAN-bus to the battery, Modbus TCP to Edge, with GX register reads.
Read commissioned building measurements from the secure-boot AS-P-NLS automation server over BACnet/IP.
Read Shelly EM Gen3 power and energy locally using HTTP RPC or MQTT. Check exact CT limits, channel identity, history and cloud-free operation.
Read Shelly Pro 3EM-3CT63 power and energy locally using HTTP RPC or MQTT. Check exact CT limits, channel identity, history and cloud-free operation.
Read Shelly Pro EM-50 power and energy locally using HTTP RPC or MQTT. Check exact CT limits, channel identity, history and cloud-free operation.
Read project-defined BACnet/IP measurements from the PXC4.E16-2 building controller, including mapped field-meter data.
Assess commissioned Siemens Desigo PXC5.E24.A BACnet objects for read-only monitoring while keeping the controller, its PPCL application and Desigo engineering authoritative.
A commercial AC charging station with two Type 2 sockets, each rated up to 22 kW. This ECC variant provides metering compliant with German calibration law. Compare its two charging points, available site power and OCPP backend setup before choosing it for a workplace or shared car park.
Monitor an HGM6120N standby generator with EpiSensor Edge through a ZEM-65 on the generator output, alongside the controller’s own measurements.
A manufacturer-independent PV plant data logger for installations up to 2 MWp, with inverter, meter, portal and optional power-management functions.
Size the CSS-OD 197 cabinet and its one or two PCS050 battery inverters using the manufacturer’s usable-energy, power and country limits.
Plan the standard SolarEdge ONE EV Charger EVN22B socket installation and its OCPP backend, and measure it in EpiSensor Edge with a ZEM-65 on its supply.
Assess the Sungrow PowerTitan 2.0 ST5015UX for read-only BESS monitoring, with exact system, safety, control and interface boundaries.
Sungrow SG320HX-20 selection guide covering its six MPPT inputs, temperature-dependent AC rating, RS485 monitoring and Sungrow PLC logger topology.
SG350HX-20 utility PV inverter selection guide covering the six-MPPT array, temperature-rated AC output and the documented RS485 or PLC-to-logger monitoring paths.
Assess Tesla Megapack 2 XL for independent read-only monitoring without displacing Tesla software, site controls, safety systems or market authority.
Niagara 4 controller for bringing existing building-system points into Edge over BACnet/IP or a configured Modbus TCP server.
Exact German, Austrian and Swiss 230 V R290 outdoor heat-pump model with a dedicated indoor-unit communication link and Vaillant system control.
Compare Lynx Smart BMS NG 500A and 1000A, Lithium NG battery compatibility, safety controls and GX-mediated monitoring.
No devices match your filters
Try a broader model fragment, manufacturer or application.
Built from public Zigbee, LoRaWAN and Modbus device definitions and manufacturer documents, including BACnet/IP guides. Exact manufacturer and model identities are joined; similar names are never assumed to be the same device.
Each device page explains the documented connection to Edge, what the device reports and how to check its setup. An Edge template is offered only where an exact reviewed import is available.
Every page cites its sources. Zigbee device photographs come from the Zigbee2MQTT project and are credited under each photograph. We never run code from these sources, and register maps are for reading: never write to a meter from a map on this site.
Tell us the manufacturer and model, and we'll look at its documentation.