WAGO 879-3000
Three-phase MID DIN-rail energy meter for direct connection up to 65 A, with RS-485 Modbus RTU, M-Bus, two S0 outputs and a hexadecimal FC03 register map of Float32 values.
- Energy meters
Meters, sensors and controllers, and how each connects to Edge.
394 device pages · 121 manufacturers with device pages
398 devices
Three-phase MID DIN-rail energy meter for direct connection up to 65 A, with RS-485 Modbus RTU, M-Bus, two S0 outputs and a hexadecimal FC03 register map of Float32 values.
Connect easYgen-2500 monitoring over Modbus RTU using OEM interface documentation.
Connect easYgen-3200XT monitoring over Modbus RTU or TCP using OEM interface documentation.
Monitor a Woodward easYgen-3500XT over its documented Modbus TCP or Modbus RTU slave interface while keeping generator, breaker, synchronising and load-share control outside Edge.
Self-powered single-phase LoRaWAN current transformers. Edge reads their decoded uplinks from your LoRaWAN network server.
Self-powered three-phase LoRaWAN current transformers with three split-core clamps. Edge reads their decoded uplinks from your LoRaWAN network server.
Monitor Terra 360 CC in EpiSensor Edge with a ZEM-65 on its AC supply, alongside the charging backend, dual-CCS2 power sharing and electrical limits.
Select the three-phase Type 2 socket variant 904460023 and connect it to EpiSensor Edge over its Modbus TCP server or a ZEM-65 on its supply.
Select and commission the European HYC400 Series 2, and measure its AC supply in EpiSensor Edge with a ZEM-65 while OCPP stays with the CPMS.
Compare original Battery-Box Premium HVS and HVM capacity, inverter compatibility and inverter-mediated monitoring.
Monitor a BYD Battery-Max Lite C&I battery through the Deye SUN-SG01HP3 hybrid that manages it: CAN to the inverter, Modbus RTU to Edge, with SOC reads.
Monitor an InteliLite NT AMF 25 generator with EpiSensor Edge through a ZEM-65 on the generator output, alongside the controller’s own interfaces.
Monitor a DSE4520 MKII standby generator with EpiSensor Edge through a ZEM-65 on the generator output, alongside the controller’s own measurements.
Monitor a DSE6120 MKIII standby generator with EpiSensor Edge through a ZEM-65 on the generator output, alongside the controller’s own measurements.
A rack-mounted high-voltage LFP battery of 3 to 12 BOS-GM5.1 modules, 15.36 to 61.44 kWh, for Deye three-phase hybrid inverters in small commercial systems.
IQ8P-3P and IQ8H-3P three-phase microinverters for 120/208 VAC small commercial PV, monitored through an IQ Gateway Commercial 2 over power line communication.
Commission the exact 22 kW, six-metre tethered Wattpilot Flex Home C6 and its OCPP 1.6 J link, and measure it in EpiSensor Edge with a ZEM-65 on its supply.
Five exact SDT G3 model codes at 8, 10, 12 and 15 kW, with two PV trackers, separate inverter-network and meter RS485 terminals, and optional communication sticks.
A commercial string-inverter family spanning 100 to 150 kW across distinct low-voltage and medium-voltage variants.
Three-phase 11 to 30 kW battery-ready PV inverter family with two or three MPPTs and separate parallel, meter, battery and backup communication connections.
A 2.5 to 6 kW single-phase battery-ready inverter family with separate RJ45 ports for the meter, third-party monitoring and a VPP protocol.
Three-phase battery-ready inverter family with two PV inputs and distinct parallel, meter, battery and SYN communication terminals.
Three-phase 4 to 25 kW hybrid inverter family for high-voltage batteries, with a generator input, backup output and dedicated meter, monitoring and EMS/VPP communication roles.
Assess a Honeywell CIPer Model 50 plant controller for monitoring through its commissioned BACnet interface without taking authority from Niagara or the controller application.
No devices match your filters
Try a broader model fragment, manufacturer or application.
Built from public Zigbee, LoRaWAN and Modbus device definitions and manufacturer documents, including BACnet/IP guides. Exact manufacturer and model identities are joined; similar names are never assumed to be the same device.
Each device page explains the documented connection to Edge, what the device reports and how to check its setup. An Edge template is offered only where an exact reviewed import is available.
Every page cites its sources. Zigbee device photographs come from the Zigbee2MQTT project and are credited under each photograph. We never run code from these sources, and register maps are for reading: never write to a meter from a map on this site.
Tell us the manufacturer and model, and we'll look at its documentation.