Phoenix Contact EEM-MA370-R
EMpro DIN-rail meter with display, external CT inputs, and both Modbus RTU over RS-485 and Modbus TCP over Ethernet.
- Energy meters
Meters, sensors and controllers, and how each connects to Edge.
394 device pages · 121 manufacturers with device pages
398 devices
EMpro DIN-rail meter with display, external CT inputs, and both Modbus RTU over RS-485 and Modbus TCP over Ethernet.
Assess the Pixii PowerShaper XL 60 kW / 225 kWh LFP system for commercial energy storage, with exact capacity, interface and control-evidence boundaries.
Four-module DIN rail easywire multifunction meter from Rayleigh Instruments for single and three-phase circuits, with a pulse output and RS485 Modbus RTU on the RI-D440-G-C.
DIN 96 easywire panel multifunction meters from Rayleigh Instruments for single and three-phase circuits, with a pulse output and an RS485 Modbus RTU port on the -G-C models; the RI-F300 is the MID certified version.
Direct-connected 65 A three-phase DIN-rail meter with RS-485 Modbus RTU, one-based FC03 registers and scaled integer values.
Eight-kilowatt single-phase R32 monobloc heat pump, with a Samsung ClimateHub or MIM-E03EN/CN control kit selected for the hydronic system.
Multi-circuit revenue meter for up to 18 three-phase or 54 single-phase circuits on SATEC HACS sensors, with RS-485 and Ethernet ports and one Modbus address per submeter.
DIN-rail three-phase energy meter with a built-in RS-485 Modbus RTU port, an optional Ethernet module for Modbus TCP, and a decimal register map with 32-bit values sent low word first.
Class 0.2S grid revenue meter and IEC 61000-4-30 class A power quality analyser with plug-in Ethernet and RS-485 modules for Modbus TCP and Modbus RTU, and a decimal register map with 32-bit integers sent low word first.
Three-phase panel power meter with a built-in RS-485 Modbus RTU port, an optional Ethernet module for Modbus TCP, and a decimal register map with 32-bit values sent low word first.
Three-phase panel power meter with a built-in RS-485 Modbus RTU port, an optional Ethernet module for Modbus TCP, and a decimal register map with 32-bit values sent low word first.
Modular class A power quality analyser and class 0.2S revenue meter with a standard Ethernet port for Modbus TCP, RS-485 ports for Modbus RTU, and a decimal register map with 32-bit integers sent low word first.
ComPacT NSX 100 to 630 moulded-case circuit breakers whose MicroLogic 5, 6 or 7 trip unit measures current and, on E types, voltage, power and energy. Edge reads them through an IFM RS-485 interface or an IFE Ethernet interface.
96 × 96 mm LED panel meter for 1 A or 5 A CTs. The RS-485 references read over Modbus RTU from Schneider's public EM6400NG register list; the pulse-output references have no Modbus port.
96 x 96 mm panel meter for 1 A or 5 A CTs. The PM2220 and PM2230 have one RS-485 Modbus RTU port and a public register list; the PM2210 has a pulse output only.
Class 0.1S DIN-rail power quality meter with two RS-485 ports and two switched Ethernet ports. Edge reads its fixed Modbus map over Modbus TCP on port 502 or Modbus RTU.
CT-connected DIN meter with local RS-485, digital I/O and a model-specific PM3200 Modbus register table.
Panel power meters for 1 A or 5 A current transformers, with Modbus RTU on RS-485 or Modbus TCP on Ethernet. Edge reads them through a Modbus interface, the Gateway’s serial port or the site network.
96 x 96 mm panel meters for 1 A or 5 A CTs. The PM5310, PM5330 and PM5331 have one RS-485 Modbus RTU port; the PM5320, PM5340 and PM5341 have one Ethernet port with Modbus TCP and BACnet/IP.
The PM5560 is a panel meter for 1 A or 5 A current transformers, with RS-485 and two Ethernet ports. Read its own electrical measurements over Modbus, while keeping downstream serial meters separate from the PM5560 endpoint.
Integrate the Schneider Electric METSEPM8240 for read-only power and power-quality monitoring over its documented Modbus interfaces.
PowerTag Energy sensors report by IEEE 802.15.4 radio to an EcoStruxure Panel Server, which gives each sensor its own Modbus TCP unit ID. Edge reads the Panel Server over Modbus TCP on port 502.
Three-phase 96 × 96 mm panel multifunction meter for 1 A or 5 A CTs, with an RS-485 Modbus RTU port and a published float register map.
Connect the 120 A Shelly Pro 3EM to Edge over Modbus TCP. A read-only triphase map, exact register offsets and a worked voltage check.
No devices match your filters
Try a broader model fragment, manufacturer or application.
Built from public Zigbee, LoRaWAN and Modbus device definitions and manufacturer documents, including BACnet/IP guides. Exact manufacturer and model identities are joined; similar names are never assumed to be the same device.
Each device page explains the documented connection to Edge, what the device reports and how to check its setup. An Edge template is offered only where an exact reviewed import is available.
Every page cites its sources. Zigbee device photographs come from the Zigbee2MQTT project and are credited under each photograph. We never run code from these sources, and register maps are for reading: never write to a meter from a map on this site.
Tell us the manufacturer and model, and we'll look at its documentation.