Siemens SENTRON PAC2200
Three-phase DIN-rail power meter with Modbus TCP on Ethernet or Modbus RTU on RS-485. Edge reads it over the site network, a Modbus interface or the Gateway’s serial port.
- Energy meters
Meters, sensors and controllers, and how each connects to Edge.
394 device pages · 121 manufacturers with device pages
398 devices
Three-phase DIN-rail power meter with Modbus TCP on Ethernet or Modbus RTU on RS-485. Edge reads it over the site network, a Modbus interface or the Gateway’s serial port.
Multichannel current measuring system: a 7KT1261 Data Manager with up to eight sensor bars and 96 current sensors, read over Modbus TCP on port 502.
DIN-rail energy meter family with RS-485 Modbus RTU versions for single-phase 63 A, three-phase x/5 A and three-phase 80 A circuits, each with its own register table.
96 × 96 mm panel meter for x/5 A CTs with an integral RS-485 Modbus RTU port, class 1 active energy to IEC 61557-12 and a published Modbus offset table.
PAC3120 is a CT-connected panel meter with built-in RS-485. Read its literal Modbus offsets, configure the serial framing and verify the meter’s CT settings before collecting power and energy.
The PAC3220 is a CT-connected panel meter with two switched Ethernet ports and local Modbus TCP. Its hardware write-protection switch can preserve a monitoring-only configuration while Edge reads power, demand and energy.
Assess an installed Siemens SENTRON PAC4200 for power and energy monitoring while keeping legacy-product, Modbus decoding and configuration-write boundaries explicit.
A CT-connected panel meter with native two-port Ethernet, a read-only Modbus TCP allowlist and complete two-register Float measurements.
Power quality recorder (7KM5412) with an Ethernet port and Modbus TCP. Measured values are big-endian Float32 holding registers; energy is a pulse count times a conversion factor.
Read SigenStack battery SOC, power and energy over Modbus TCP from its Sigen Hybrid M1-HYA inverter, with plant address 247 and V2.7 registers.
Connect the Sinexcel PWS1-500KTL modular PCS to EpiSensor Edge over Modbus TCP or Modbus RTU, with the EMS, BMS and point-list boundaries a C&I storage project needs.
Sunny Boy Storage 5.0 adds high-voltage battery storage on the AC side of an existing PV installation. It supplies 5 kW on a single phase and has three separately managed battery inputs. It is a battery inverter, not a PV string inverter: keep the existing solar inverter and distinguish the manual emergency outlet from an automatic battery-backup installation.
Assess the SMA Sunny Central Storage UP battery inverter for read-only monitoring, with exact model, Modbus role, battery and plant-control boundaries.
Monitor Sunny Island battery state, voltage, current and inverter power through its local SMA Modbus TCP interface.
Read Sunny Island X device type, battery state of charge, battery power and AC values over the SMA Modbus TCP profile, unit ID 3, with the firmware 3.04.80.R parameter list.
Read local inverter and battery measurements through the SMA Modbus interface, with explicit firmware scope and separate site-meter measurements.
Compare the SMA Sunny Tripower CORE1 STP 50-40 and 50-41, including firmware scope, default-off Modbus and a safe read-only monitoring plan.
Sixty-kilowatt STP 60-80 commercial PV inverter with five MPP trackers and a configurable Modbus interface.
CORE2 STP 110-60 is a 110 kW three-phase PV inverter with 12 MPP trackers.
A 25 kW three-phase PV inverter with three MPPTs and an integrated system manager. Read its own device values separately from whole-system measurements.
Connect HGM7220N monitoring over Modbus RTU using OEM interface documentation.
Connect HGM9510 monitoring over Modbus RTU using OEM interface documentation.
Connect HGM9560 monitoring over Modbus RTU using OEM interface documentation.
Direct 80 A three-phase meters: choose E23 or E24 MID, match RS-485 settings and understand the tariff and billing-data boundaries.
No devices match your filters
Try a broader model fragment, manufacturer or application.
Built from public Zigbee, LoRaWAN and Modbus device definitions and manufacturer documents, including BACnet/IP guides. Exact manufacturer and model identities are joined; similar names are never assumed to be the same device.
Each device page explains the documented connection to Edge, what the device reports and how to check its setup. An Edge template is offered only where an exact reviewed import is available.
Every page cites its sources. Zigbee device photographs come from the Zigbee2MQTT project and are credited under each photograph. We never run code from these sources, and register maps are for reading: never write to a meter from a map on this site.
Tell us the manufacturer and model, and we'll look at its documentation.