Alfen Eve Single Pro-line 904460023

AC EV charger

Alfen article 904460023 is the three-phase Eve Single Pro-line with a Type 2 socket and display. The current datasheet states up to 22 kW at 32 A per phase, a MID-certified meter, Ethernet, cellular and Wi-Fi options, and certified OCPP 1.6 JSON with optional OCPP 2.0.1 support. It also lists external smart-charging inputs. Alfen's Smart Charging manual documents a local Modbus TCP server for an energy management system, so the charger is compatible with EpiSensor Edge over Modbus TCP. The OCPP link stays with the charging backend.

Alfen Eve Single Pro-line 904460023
  • OCPP 1.6 JSON
  • OCPP 2.0.1 JSON
  • Ethernet

AC EV charger

Ask an engineer

Compatibility

Compatible with EpiSensor Edge over Modbus TCP

Alfen's Smart Charging manual v1.1 (October 2025) documents the charger as a Modbus TCP server for an energy management system on port 502, which Edge's Modbus TCP client reads. An EpiSensor ZEM-65 electricity monitor with CTs on the charger's supply is a second route for energy, power and current per phase. The OCPP 1.6 JSON link stays with the charging backend; Edge does not speak OCPP.

Exact article 904460023: three-phase Pro-line with display and Type 2 socket. Fixed-cable 904460027, shutter socket 904460025, one-phase models, S-line and German DE/Eichrecht variants differ. Site check: obtain Alfen's NG9xx register specification for the installed firmware, and agree the safe current with the installer, because a read-only client sends no current setpoints.

Connect it with

Route into Edge

When Active Load Balancing is unlocked and TCP/IP EMS is selected in ACE Service Installer

  • Modbus
  • Edge
  • Platforms
AC EV charger
Interface
Gateway
Edge
Output
Eve Single Pro-line 904460023Eve Single Pro-line wired LAN, Modbus TCP port 502
Protected EthernetSegmented LAN
ZGW-20 GatewayHosts Edge locally
EpiSensor EdgeModbus client + register map
Customer platformMQTT · API · files
Modbus TCP
Protected Ethernet
Runs locally
Optional onward data
Alfen's Smart Charging manual v1.1 documents the server on the wired IPv4 LAN without PoE, port 502, with unit 200 for station registers and unit 1 for this socket, Big Endian data. Map points from Alfen's separate NG9xx register specification for the installed firmware. Keep Edge read only: the charger returns to its configured safe current when no energy manager refreshes a setpoint within the validity time, so set that current with the installer. The customer-platform output is optional; Edge remains the local system of record.

For energy, power and current per phase on a three-phase charger circuit, with or without a charger data connection

  • Wired
  • Edge
  • Platforms
AC EV charger
Interface
Gateway
Edge
Output
Eve Single Pro-line 904460023Eve Single Pro-line three-phase circuit
ZEM-65 electricity monitorMeasures energy, power and current per phase on the charger supply
ZGW-20 GatewayHosts Edge locally
EpiSensor EdgeEdge: energy, power and current per phase
Customer platformMQTT · API · files
CTs and voltage reference
EpiSensor wireless
Runs locally
Optional onward data
A qualified electrician fits the ZEM-65's 120 A split-core CTs on L1, L2 and L3 of the charger's dedicated circuit and connects its voltage reference. The ZEM-65 sends energy, power and current per phase over the EpiSensor wireless network to the Gateway, where Edge records them. It measures what the circuit draws, including standby, not the vehicle's state of charge or the backend's session records. The customer-platform output is optional; Edge remains the local system of record.

Models

Download
ModelsInterfaceRoute into Edge
904460023, Pro-line three-phase Type 2 socketUp to 22 kW, display, MID meter, Ethernet and OCPP 1.6 JSONModbus TCP server on port 502 for Edge, or a ZEM-65 on the supply; OCPP stays with the charging backend.
904460025 / 904460027 and one-phase variantsShutter socket, fixed cable or one-phase alternativesConfirm the article number before using connector, power or enclosure dimensions from this guide.

Specifications

The Alfen datasheet lists six Pro-line article numbers. This guide owns only 904460023 and uses the family table where it explicitly applies to that three-phase socket variant.12

AC output
Three-phase 400 V, up to 32 A per phase and 22 kW; actual power depends on vehicle and grid connection2
Connector and display
One Type 2 socket and 3.5-inch colour display2
Metering
MID-certified energy meter; separate DE variants add a German Eichrecht boundary12
Backend
Certified OCPP 1.6 JSON; OCPP 2.0.1 JSON subject to Alfen's latest support overview2
Networks and inputs
Ethernet and configured cellular/Wi-Fi options; P1/DSMR, Modbus RTU external meter and TIC; local Modbus TCP server for an EMS, separate from the external-meter client role23
Environment
IP55, IK10, -25 to +55 °C; 22 kW guaranteed only between -25 and +40 °C2

Interface

Documented measurements and integration boundaries for Eve Single Pro-line 904460023.

  • Article number 904460023 identifies the three-phase Type 2 socket form. Connector and cable variants must remain separate in procurement and asset records.
  • OCPP 2.0.1 availability is marked with a requirement to consult Alfen's latest support overview. Confirm the installed firmware and licence rather than relying on the family datasheet alone.
  • The MID-certified meter supports accurate consumption registration, but billing also depends on national rules, backend data handling and the operating process.

Assessment

Exact article 904460023; Modbus TCP server for an EMS and OCPP 1.6 JSON documented, with no German Eichrecht claim or universal OCPP 2.0.1 availability.

InteroperabilitySupported with conditions
Certified OCPP 1.6 and a local Modbus TCP server for an EMS are documented, with port, unit IDs and byte order; individual registers are in Alfen's separate NG9xx specification.23
AccuracySupported with conditions
A MID-certified meter is documented; national billing rules and the backend's transaction handling also apply.12
SecuritySupported with conditions
TLS 1.2, X.509, basic authentication and signed firmware are documented; the operator must configure the selected backend securely.2
ReliabilitySupported with conditions
Protection, transaction storage, diagnostics and environmental limits are published; reconnection and backend recovery need commissioning evidence.2
RuggednessSupported with conditions
IP55, IK10 and temperature limits are documented, including reduced guaranteed-power conditions above 40 °C.2
ScalabilitySupported with conditions
The product page describes up to 100 single-socket units in a smart-charging network, subject to backend and site design.1
LifecycleSupported with conditions
Alfen publishes current product, technical and security details; preserve article number, firmware, licences and configuration for replacement.12

Setup

  1. Check the label and order record for article 904460023, three-phase supply, Type 2 socket and Pro-line display.

    Do not substitute shutter, cable, one-phase or DE variants by appearance.

  2. Have an authorised installer verify the dedicated circuit, Type A RCD, integrated 6 mA DC detection, earthing, cable size and manufacturer temperature limits.

  3. Record firmware, enabled communications and licences.

    Agree the OCPP version, TLS and credential policy, endpoint, charge-point identity and meter-value interval with the chosen backend.

  4. For local EMS control, unlock Active Load Balancing (ALB) and select TCP/IP EMS in ACE Service Installer.

    Use the wired IPv4 LAN without PoE, port 502, unit 200 for station registers and unit 1 for this single socket, with Big Endian data. Choose individual-socket or Smart Charging Network mode and configure the safe current and validity time, default 60 seconds. The EMS must refresh its current setpoint within that time; loss of updates returns charging to the safe current. In Live monitoring, check Modbus Connection State and Currents during a charging session. Installer account access is required for ACE Service Installer.

  5. Test socket lock, RFID or Plug & Power, charge start/stop, meter values, network loss and recovery.

    Compare the same transaction at the local display and backend.

Common questions

Is article 904460023 the fixed-cable model?
No. It is the three-phase Pro-line with a Type 2 socket. Article 904460027 is the fixed-cable variant and 904460025 is the shutter-socket variant.2
Is OCPP 2.0.1 available on every installed unit?
The datasheet lists OCPP 2.0.1 with an instruction to consult Alfen's latest support overview. Confirm firmware, licence and backend support for the installed charger.2
Can an EMS connect locally over Modbus TCP?
Yes. Alfen’s Smart Charging configuration manual v1.1, October 2025, documents the charger as a Modbus TCP server for an EMS, including port 502, unit IDs, byte order and current-limit timeout. Its external-meter client role is a different connection. The manual refers to a separate NG9xx register specification for individual points. Edge's Modbus TCP client reads this server; map points from the NG9xx revision that matches the installed firmware.3