Alpha ESS STORION-H30/H50-G3
Monitor the Alpha ESS STORION-H29.9, H30 and H50-G3 all-in-one C&I cabinets with EpiSensor Edge: the EMS Modbus TCP dispatching interface, the AC feeder and the control boundary.
- Battery systems and controls
Meters, sensors and controllers, and how each connects to Edge.
24 device pages · 120 manufacturers with device pages
24 devices
Monitor the Alpha ESS STORION-H29.9, H30 and H50-G3 all-in-one C&I cabinets with EpiSensor Edge: the EMS Modbus TCP dispatching interface, the AC feeder and the control boundary.
A 200 kW, 430.08 kWh liquid-cooled LFP cabinet with two 100 kW PCS modules, battery management and fire suppression for commercial and industrial sites.
A 250 kW, 522.496 kWh liquid-cooled LFP cabinet for commercial and industrial sites, with its PCS, battery, cooling and fire suppression in one enclosure.
A 200 kW, 482.304 kWh liquid-cooled LFP cabinet that stores PV and grid energy for DC fast charging at commercial charging sites.
Read FENECON Commercial 92 state of charge, battery power, grid and PV values through the FEMS Modbus/TCP read interface, which ships pre-installed.
Read Huawei LUNA2000-200KWH-2H1 SOC, power and energy over Modbus TCP from its CMU with the LUNA2000B port definitions, or through a SmartLogger3000.
Read Huawei LUNA2000-215-2S10 SOC, power and capacity over Modbus TCP through the SmartLogger3000 that manages it, with SmartLogger issue 43 ESS registers.
Assess the Huawei LUNA2000-241-2S1 C&I ESS for read-only monitoring, with Modbus TCP, controller, safety and measurement boundaries.
Read the INGECON SUN STORAGE 100TL battery inverter over Modbus TCP: AC power, DC power, battery state of charge, status and alarms from Ingeteam's input-register map.
Assess the current INTILION scalepac C&I battery system for operational monitoring, with configuration, interface and control boundaries.
Read TriStar MPPT 60 battery and array measurements over Ethernet, using the controller’s own voltage and current scaling registers.
Read Nuvation G5 battery-stack status through SunSpec Modbus TCP while preserving the existing battery controller’s connection and safety responsibilities.
Assess the Pixii PowerShaper XL 60 kW / 225 kWh LFP system for commercial energy storage, with exact capacity, interface and control-evidence boundaries.
Connect the Sinexcel PWS1-500KTL modular PCS to EpiSensor Edge over Modbus TCP or Modbus RTU, with the EMS, BMS and point-list boundaries a C&I storage project needs.
Sunny Boy Storage 5.0 adds high-voltage battery storage on the AC side of an existing PV installation. It supplies 5 kW on a single phase and has three separately managed battery inputs. It is a battery inverter, not a PV string inverter: keep the existing solar inverter and distinguish the manual emergency outlet from an automatic battery-backup installation.
Assess the SMA Sunny Central Storage UP battery inverter for read-only monitoring, with exact model, Modbus role, battery and plant-control boundaries.
Monitor Sunny Island battery state, voltage, current and inverter power through its local SMA Modbus TCP interface.
Read Sunny Island X device type, battery state of charge, battery power and AC values over the SMA Modbus TCP profile, unit ID 3, with the firmware 3.04.80.R parameter list.
Connect the Sungrow PowerStack 255CS (ST255CS-2H) to Edge over Modbus TCP from its EMS300CP, or measure its 400 V AC feeder with an EpiSensor ZEM-65.
Read TS-I HV 80 state of charge, battery power, grid and PV power through the TESVOLT Energy Manager's Modbus TCP marketer interface on port 1505.
Read battery, inverter/charger and solar-charger data through the Cerbo GX MK2 local Modbus TCP gateway.
Read MultiPlus-II AC input, AC output, battery and alarm values through the GX device's Modbus TCP server, using the VE.Bus service unit ID.
Read Quattro AC input, active-source, battery and alarm values through the GX device's Modbus TCP server, including which of the two AC inputs is live.
Three-phase 4 to 25 kW hybrid inverter family for high-voltage batteries, with a generator input, backup output and dedicated meter, monitoring and EMS/VPP communication roles.
No devices match your filters
Try a broader model fragment, manufacturer or application.
Built from public Zigbee, LoRaWAN and Modbus device definitions and manufacturer documents, including BACnet/IP guides. Exact manufacturer and model identities are joined; similar names are never assumed to be the same device.
Each device page explains the documented connection to Edge, what the device reports and how to check its setup. An Edge template is offered only where an exact reviewed import is available.
Every page cites its sources. Zigbee device photographs come from the Zigbee2MQTT project and are credited under each photograph. We never run code from these sources, and register maps are for reading: never write to a meter from a map on this site.
Tell us the manufacturer and model, and we'll look at its documentation.