One probe or two
TES-21 reads a single probe and TES-22 reads two, each on its own channel, from one battery-powered sensor.
TES-2X
Battery-powered wireless probes for pipes, cold stores and equipment, accurate to ±0.2 °C across the normal range. One probe or two, in the style and cable length the job needs, for up to ten years on one cell.
From €199 ex VAT
Works with the Gateway
TES-21 reads a single probe and TES-22 reads two, each on its own channel, from one battery-powered sensor.
Up to ten years from one user-replaceable lithium cell, estimated at 23 °C with full wireless coverage.
Every probe uses a 10k NTC thermistor.
0.01 °C resolution, and ±0.5 °C across the full −40 °C to 105 °C range.
IP68 probes and an IP67 polycarbonate enclosure, rated to operate from −30 °C to 55 °C.
Up to 70,000 readings are kept in flash on the sensor, time-stamped, and sent when the link returns.
Choose the options for your site. The summary shows the line that goes into your cart.
Not sure this is the right product for your site? Build a system
It reports over the Zigbee mesh to the Gateway, which runs Edge on site.
GatewayUp to 250 devices on one Gateway, with Edge pre-installed and no licence needed for EpiSensor devices.
The waterproof TPE probes suit air and liquids in cold rooms, fridges and tanks, on a short lead or a 1.5 m or 2.5 m cable. The pipe probe has a flattened stainless tip that sits against a pipe, for flow and return or hot-water checks. The steel general-purpose probe has a stainless cap for places where a metal probe is preferred.
±0.2 °C across the normal range (−20 °C to 70 °C for the waterproof probe, 0 °C to 70 °C for the steel probes) and ±0.5 °C across the full −40 °C to 105 °C range, at 0.01 °C resolution.
Up to ten years at 15-minute reporting, estimated at 23 °C with full wireless coverage. A shorter interval, a colder site or a weak signal shortens it. The A-size lithium cell is replaced by the user.
The sensor keeps measuring and holds up to 70,000 readings in flash, so the record has no gap when the link comes back.
Yes. Each probe can be calibrated by EpiSensor at one point, or to UKAS at three points (0 °C, 5 °C and 10 °C by default). Ask us when you order.
It reports to a ZGW-20 Gateway, which stores the readings, raises alarms in Edge and sends the data on to your platform.