Eastron SDM630-Modbus
Direct-connected three-phase meter up to 100 A with an RS-485 Modbus RTU port. Edge reads it through a Modbus interface or the Gateway’s serial port.
- Energy meters
Meters, sensors and controllers, and how each connects to Edge.
136 device pages · 37 manufacturers with device pages
407 devices
Direct-connected three-phase meter up to 100 A with an RS-485 Modbus RTU port. Edge reads it through a Modbus interface or the Gateway’s serial port.
Panel power meters for 1 A or 5 A current transformers, with Modbus RTU on RS-485 or Modbus TCP on Ethernet. Edge reads them through a Modbus interface, the Gateway’s serial port or the site network.
Connect the 120 A Shelly Pro 3EM to Edge over Modbus TCP. A read-only triphase map, exact register offsets and a worked voltage check.
Three-phase DIN-rail power meter with Modbus TCP on Ethernet or Modbus RTU on RS-485. Edge reads it over the site network, a Modbus interface or the Gateway’s serial port.
ABB's MID-approved three-phase DIN-rail energy meters: the B23 connects directly up to 65 A and the B24 reads current transformers with a secondary of up to 6 A. Edge reads it through a Modbus interface or the Gateway’s serial port.
ABB's 96 × 96 mm panel network analysers for 1 A or 5 A current transformers, with Class 0.5S active energy, harmonics to the 40th and a colour display. Edge reads it through a Modbus interface or the Gateway’s serial port.
A three-phase DIN-rail energy analyser for direct connection up to 65 A or through current transformers, with Class 1 active energy and, on IS models, a Modbus RTU port on RS-485. Edge reads it through a Modbus interface or the Gateway’s serial port.
Two three-phase DIN-rail energy meters on one register map: the EM340 connects directly up to 65 A and powers itself, the EM330 reads 5 A current transformers. Edge reads it through a Modbus interface, the Gateway’s serial port or the site network.
A single-phase energy transducer with no display, two DIN modules wide, for direct connection up to 100 A. Edge reads it through a Modbus interface or the Gateway’s serial port.
A three-phase, four-wire DIN-rail energy meter that reads current transformers, with Class 1 active energy, per-phase import and export counters and an RS-485 Modbus RTU port, in a 72 mm housing. Edge reads it through a Modbus interface or the Gateway’s serial port.
A three-phase, four-wire DIN-rail energy meter for direct connection up to 100 A, with import and export energy, resettable counters and an RS-485 Modbus RTU port, in a 72 mm housing that needs no auxiliary supply. Edge reads it through a Modbus interface or the Gateway’s serial port.
A single-phase DIN-rail energy meter one module wide, for direct connection up to 45 A, with MID Class B active energy, separate import and export counters and an RS-485 Modbus RTU port. Edge reads it through a Modbus interface or the Gateway’s serial port.
Two single-phase DIN-rail energy meters, two modules wide, for direct connection up to 100 A, with import and export energy, demand values and an RS-485 Modbus RTU port on one shared register map. Edge reads it through a Modbus interface or the Gateway’s serial port.
A 4-module DIN-rail power analyser that runs from the voltage it measures and reads 1 A or 5 A current transformers, with Class 0.5S energy on 5 A CTs and harmonics to the 25th. Edge reads it through a Modbus interface or the Gateway’s serial port.
Schneider Electric's DIN-rail energy meters with a Modbus RTU port: the iEM3150 and iEM3155 up to 63 A, the iEM3350 and iEM3355 up to 125 A, and the iEM3250 and iEM3255 on 1 A or 5 A current transformers. Edge reads it through a Modbus interface or the Gateway’s serial port.
A 96 × 96 mm panel meter for low-voltage distribution, on 1 A or 5 A current transformers, with Class 0.5S active energy and more than 50 measured values. Edge reads it through a Modbus interface or the Gateway’s serial port.
A 96 × 96 mm panel meter with a touchscreen that measures energy, power and power quality through Socomec's own plug-in current sensors, which it recognises by type and rating. Edge reads it through a Modbus interface, the Gateway’s serial port or the site network.
Power meter. Reports voltage, current, power, cumulative energy and frequency with device status.
Energy meter. Reports power and cumulative energy, in charge-point, grid and solar roles. Connects over Modbus RTU (RS-485).
Energy meter. Reports power and cumulative energy, in charge-point, grid and solar roles. Connects over Modbus RTU (RS-485).
Energy meter. Reports power and cumulative energy, in charge-point, grid and solar roles. Connects over Modbus RTU (RS-485).
Energy meter. Reports power and cumulative energy, in charge-point, grid and solar roles. Connects over Modbus RTU (RS-485).
Solar inverter. Reports voltage, current, power, cumulative energy and temperature with device status.
Power meter. Reports voltage, current, power, cumulative energy and harmonic distortion with device status.
No devices match your filters
Try a broader model fragment, manufacturer or application.
Built from public Zigbee, LoRaWAN and Modbus device definitions and manufacturer documents. Exact manufacturer and model identities are joined; similar names are never assumed to be the same device.
A device that documents Zigbee 3.0, LoRaWAN or Modbus support connects to EpiSensor Edge through that protocol. A device page lists what the device reports, how to set it up and, where one exists, the Edge template for it.
Every page cites its sources. Zigbee device photographs come from the Zigbee2MQTT project and are credited under each photograph. We never run code from these sources, and register maps are for reading: never write to a meter from a map on this site.
Tell us the manufacturer and model, and we'll look at its documentation.