Schneider Electric CCTFR6100Z3
Radiator thermostat
A battery-powered Zigbee radiator valve head from Schneider Electric’s Wiser range, set from 5 to 30 °C in 0.5 °C steps, with an M30 × 1.5 ring nut and a Danfoss RA adapter in the box.
Also sold asWiser Radiator Thermostat Z3
- Zigbee
Radiator thermostat
Compatibility
Compatible with EpiSensor Edge over Zigbee.
Pair it with the Zigbee radio on an EpiSensor Gateway. Edge reads it locally on the Gateway.
Edge reads 5 values from it, listed under Interface.
Connect it with
-
Gateway ZGW-20From €899 ex VAT Configure Gateway
Specifications
It is built for wet heating systems: Schneider rates it for water at 73 °C continuously and 110 °C at most, on a valve whose surface stays at or below 93 °C. It works in rooms from 0 to 45 °C and is rated IP30, so it belongs indoors in dry rooms.1
- Power
- Battery. Two 1.5 V AA alkaline cells, supplied with the thermostat.1
- Setpoint range
- 5 to 30 °C, 0.5 °C steps1
- Local adjustment
- Twist cap, ±2 °C1
- Valve connection
- M30 × 1.5 ring nut; adapter for Danfoss RA valves1
- Heating water
- 73 °C continuous, 110 °C maximum1
- Valve surface temperature
- 93 °C maximum1
- Operating temperature
- 0 to 45 °C1
- Storage temperature
- -10 to 55 °C1
- Relative humidity
- 25 to 90 % operating1
- Wireless
- Zigbee, 2.4 GHz, 13 dBm (20 mW) maximum1
- Radio range
- 0 to 30 m1
- Protection
- IP30, pollution degree 21
- Dimensions
- 51 mm diameter, 93 mm high1
- Standards
- EN 60730-1, EN 60730-2-7, EN 60730-2-9, EN 300 3281
Where it is used
Room-by-room radiator control in offices, schools and housing, with schedules and set-backs held centrally in Edge automations.
Indoor environmental monitoringReading heating demand from every radiator to see which rooms keep the boiler running, and setting them back outside occupied hours.
Boiler performance monitoring
Interface
Readings and settings, with units and ranges where Schneider Electric publishes them. readable, readable and writable.
| Reading | Unit | Range or values | Access |
|---|---|---|---|
| Measurements 4 | |||
| Climate | - | - | Read only |
| Local temperature | °C | - | Read only |
| Running state | - | idleheat |
Read only |
| Pi heating demand | % | 0 to 100 % | Read only |
| Controls 1 | |||
| Occupied heating setpoint | °C | 7 to 30 °C | Read and write |
The thermostat reports its model as CCTFR6100 and uses the standard Zigbee thermostat cluster: local temperature, occupied heating setpoint, PI heating demand and running state.3
Its Zigbee definition writes the setpoint from 7 to 30 °C in 1 °C steps, a narrower range than the 5 to 30 °C the head accepts locally.13
Heating demand is the valve position: 0 % is fully closed and 100 % fully open. Running state reads heat while it is calling for heat and idle otherwise.2
Setup
-
Fit it to the valve
Screw the supplied M30 × 1.5 ring nut onto the valve, or fit the Danfoss RA adapter first on an RA valve, then mount the head.1
-
Insert the batteries
Fit the two AA alkaline cells supplied with it.1
-
Open pairing in Edge
In Edge, open pairing on the Gateway’s Zigbee network and put the thermostat into pairing mode as its leaflet describes. A thermostat already joined to another Zigbee network, such as a Wiser system, has to leave it or be reset first.
-
Check one reading and one setting
Confirm Edge identifies it as Schneider Electric CCTFR6100Z3. Compare the local temperature with a thermometer in the room, then write a setpoint a few degrees above it and check the heating demand rises.
Sources
- Radiator Thermostat, Wiser, Z3, white: CCTFR6100Z3 product datasheet (opens in a new tab)
- Schneider Electric CCTFR6100Z3 (opens in a new tab)
- Schneider Electric device definitions (schneider_electric.ts), v26.111.0 (opens in a new tab)
Further reading
Product names and trademarks belong to their owners. Publication does not imply endorsement or a commercial relationship.