ComAp InteliMains 210
Mains supervision controller
InteliMains 210 supervises the mains connection and associated switchgear in a generator installation. It belongs at the mains or tie-breaker part of the plant model. It does not replace the engine controller on each generating set.
Compatibility
Compatible with EpiSensor Edge over Modbus TCP or Modbus RTU
Integrated isolated RS-485; optional CM-Ethernet or CM-RS232-485 communication modules
The MCB, MGCB and BTB applications describe different breaker arrangements. ComAp identifies InteliMains 210 G2 as the successor to this discontinued model.
Connect it with
When the documented monitoring interface is fitted and configured
- Modbus
- Edge
- Platforms
When the documented monitoring interface is fitted and configured
- Modbus
- Edge
- Platforms
Models
| Models | Interface | Route into Edge |
|---|---|---|
| InteliMains 210 | Integrated isolated RS-485; optional CM-Ethernet or CM-RS232-485 communication modules | Record the active MCB, MGCB or BTB application in InteliConfig. Export the Modbus table and label observations by the actual mains, group or bus-tie breaker position rather than applying generator names to every value. |
Specifications
The MCB, MGCB and BTB applications describe different breaker arrangements. ComAp identifies InteliMains 210 G2 as the successor to this discontinued model.12
- Plant role
- Mains supervision controller1
- Monitoring and configuration
- Integrated isolated RS-485; optional CM-Ethernet or CM-RS232-485 communication modules2
- Model distinction
- The MCB, MGCB and BTB applications describe different breaker arrangements. ComAp identifies InteliMains 210 G2 as the successor to this discontinued model.12
- Panel protection
- IP65 front panel and IP20 rear; standard operating temperature -20 to +70 °C.2
Interface
Documented measurements and integration boundaries for InteliMains 210.
- Mains electrical measurements and configured power quantities
- Mains or bus-tie breaker position and controller mode
- Mains supervision alarms and application-specific group status
Assessment
Integrated isolated RS-485; optional CM-Ethernet or CM-RS232-485 communication modules
- InteroperabilitySupported with conditions
- Integrated isolated RS-485; optional CM-Ethernet or CM-RS232-485 communication modules12
- AccuracySupported with conditions
- The documentation identifies electrical and operating measurements for this plant role. CT configuration and measurement location determine how those values are used.12
- SecurityNot yet assessed
- The cited documentation does not establish an authenticated, encrypted Edge monitoring connection.
- ReliabilityNot yet assessed
- The controller application distinguishes operating conditions and alarms. Retain communication availability alongside the plant readings.
- RuggednessSupported with conditions
- IP65 front panel and IP20 rear; standard operating temperature -20 to +70 °C.2
- ScalabilityNot yet assessed
- Assign one device identity per controller and keep generator, mains and busbar measurements separate.
Setup
-
Record the active MCB, MGCB or BTB application in InteliConfig.
Export the Modbus table and label observations by the actual mains, group or bus-tie breaker position rather than applying generator names to every value.
-
Record CT ratios and the physical measurement location.
Compare the first electrical values with the controller display before using them in totals or trends.
-
Keep missing responses distinct from a stopped generator.
Store communication availability beside running state so a disconnected cable does not look like healthy standby.
-
Build a read-only point list for monitoring.
Remote start, synchronisation and breaker operation require a separate control design with the existing panel interlocks and feedback.
Sources
Further reading
Product names and trademarks belong to their owners. Publication does not imply endorsement or a commercial relationship.