A battery Zigbee 3.0 monitor for total volatile organic compounds, temperature and humidity, with an E Ink display. It reads TVOC from 0 to 25 mg/m³ at 1 ppb resolution and gives a five-step air quality rating alongside the number.
Also sold asAqara TVOC Air Quality Monitor
- Zigbee
TVOC air quality monitor
Compatibility
Compatible with EpiSensor Edge over Zigbee.
Pair it with the Zigbee radio on an EpiSensor Gateway. Edge reads it locally on the Gateway.
Edge reads 8 values from it, listed under Interface.
Connect it with
-
Gateway ZGW-20From €899 ex VAT Configure Gateway
Specifications
Besides the concentration it reports an air quality level: excellent, good, moderate, poor or unhealthy. Aqara does not publish the concentrations behind each level, so for thresholds of your own, work from the TVOC value rather than the level.15
- Power
- Battery. Two CR2450 coin cells, rated for more than one year.3
- TVOC range
- 0 to 25 mg/m³1
- TVOC resolution
- 1 ppb or 0.01 mg/m³2
- Temperature resolution
- 0.1 °C2
- Humidity range
- 0 to 100 % RH, 1 % RH resolution2
- Operating conditions
- 0 to 50 °C, 0 to 95 % RH non-condensing1
- Display
- Dot-matrix E Ink3
- Wireless
- Zigbee 3.0, 2405 to 2480 MHz, 13 dBm maximum1
- Dimensions
- 41.6 × 76.0 × 14 mm1
- Mounting
- Freestanding, adhesive, or magnetic sticker on steel; 2 m high at most1
- Environment
- Indoor use only1
- Model number
- AAQS-S011
Where it is used
Indoor air quality in offices, classrooms and meeting rooms, especially after refurbishment, new furniture or a change of cleaning products.
Indoor environmental monitoringChecking that ventilation schedules keep pollutant levels down in occupied rooms, alongside the energy the ventilation uses.
HVAC energy monitoring for commercial buildingsStores, workshops and print rooms where solvents, adhesives or inks are used, as an early sign that extraction is not keeping up.
Interface
Readings and settings, with units and ranges where Aqara publishes them. readable, readable and writable.
| Reading | Unit | Range or values | Access |
|---|---|---|---|
| Measurements 4 | |||
| Air quality | - | excellentgoodmoderatepoorunhealthyunknown |
Read only |
| VOC | ppb | - | Read only |
| Temperature | °C | - | Read only |
| Humidity | % | - | Read only |
| Settings 1 | |||
| Display unit | - | mgm3_celsiusppb_celsiusmgm3_fahrenheitppb_fahrenheit |
Read and write |
| Diagnostics 3 | |||
| Device temperature | °C | - | Read only |
| Battery | % | 0 to 100 % | Read only |
| Voltage | mV | - | Read only |
TVOC arrives in ppb as the present value of the Analog Input cluster. Temperature and humidity use the standard measurement clusters. The air quality level, the display unit and the device's internal temperature sit in Aqara's manufacturer-specific cluster.5
TVOC reporting is configured with a 10-second minimum interval, a 1-hour maximum interval and a reportable change of 5 ppb.5
Display unit is the one writable setting: mg/m³ or ppb for TVOC, and °C or °F for temperature. It only changes what the E Ink screen shows; mg/m³ and °C are the default.5
The monitor supports over-the-air firmware updates over Zigbee.45
Setup
-
Fit the batteries
Open the battery cover and fit the two CR2450 cells. Keep the sensor holes on the case clear.1
-
Open pairing in Edge
In Edge, open pairing on the Gateway's Zigbee network. The Gateway accepts new devices while pairing is open.
-
Hold the button
Press and hold the button on top of the monitor until the network symbol appears on the display. It shows a searching icon while it looks for the network and a connected icon once it has joined.4
-
Test the location
Put the monitor where it will live and click the button once. Aqara uses this press as its range test: check that Edge receives the update, and if it does not, move the monitor closer to the Gateway.1
-
Check the readings
Confirm that Edge shows TVOC, temperature and humidity, and compare temperature and humidity with a reference instrument. Give the TVOC reading time to settle after installation before you set thresholds on it.
Common questions
- Does it measure CO₂?
- No. It measures TVOC, temperature and humidity only. TVOC tracks solvents and other organic compounds, not carbon dioxide, so it does not show how many people a room holds or whether fresh air matches occupancy.1
- Does it need an Aqara hub to work with Edge?
- No. Aqara's app setup uses an Aqara hub, but the monitor is a Zigbee 3.0 device, so it pairs with the Zigbee radio on an EpiSensor Gateway and Edge reads it directly.1
- Is the reading in ppb or mg/m³?
- Over Zigbee the TVOC value is reported in ppb. The display can show either ppb or mg/m³, set by its display unit setting, which does not change the value Edge receives.25
- How long do the batteries last?
- Aqara rates the two CR2450 coin cells for more than one year. Edge reports battery voltage and percentage so the cells can be changed before the readings stop.3
- Where should it be mounted?
- Indoors, at a height of 2 m or less, away from heaters and other heat sources. It can stand on a desk, stick on with adhesive or hold to steel with its magnetic sticker.1
Sources
- TVOC Air Quality Monitor manual (AAQS-S01) (opens in a new tab) (PDF)
- TVOC Air Quality Monitor specifications (opens in a new tab)
- TVOC Air Quality Monitor (opens in a new tab)
- Aqara VOCKQJK11LM device notes (opens in a new tab)
- Aqara device definitions (VOCKQJK11LM) (opens in a new tab)
Further reading
Product names and trademarks belong to their owners. Publication does not imply endorsement or a commercial relationship.