Develco AQSZB-110
Air quality sensor
A battery-powered Zigbee sensor for total VOC, temperature and relative humidity, sold as the frient Air Quality Sensor. It measures VOC from 0 to 60,000 ppb and runs for up to two years on two AA cells when reporting every 5 minutes.
Also sold asfrient Air Quality Sensor
- Zigbee
Air quality sensor
Compatibility
Compatible with EpiSensor Edge over Zigbee.
Pair it with the Zigbee radio on an EpiSensor Gateway. Edge reads it locally on the Gateway.
Edge reads 7 values from it, listed under Interface.
Connect it with
-
Gateway ZGW-20From €899 ex VAT Configure Gateway
Specifications
The VOC sensor measures in parts per billion from 0 to 60,000 ppb, with a resolution of 1 ppb up to 2008 ppb, 6 ppb up to 11,110 ppb and 32 ppb above that. Develco publishes a five-level interpretation of the reading, from excellent below 65 ppb to unhealthy from 2200 ppb, taken from Sensirion’s TVOC guidance. Temperature has 0.1 °C resolution with a typical accuracy of ±0.2 °C; humidity has 1 % RH resolution with a typical accuracy of 2 % between 20 and 80 % RH.23
- Power
- Battery. Two exchangeable AA alkaline cells, rated for 2 years when reporting every 5 minutes. Develco says to replace them when the battery voltage reaches 2.5 V.2
- VOC range
- 0 to 60,000 ppb2
- VOC resolution
- 1 to 32 ppb, coarser at higher readings3
- Temperature range
- 0 to 50 °C2
- Temperature accuracy
- ±0.2 °C typical, 0.1 °C resolution2
- Temperature sample time
- 30 s2
- Humidity range
- 0 to 100 % RH2
- Humidity accuracy
- 2 % typical between 20 and 80 % RH, 1 % RH resolution2
- Operating humidity
- 10 to 95 % RH, non-condensing3
- Ingress protection
- IP201
- Dimensions
- 70 × 70 × 21 mm2
- Weight
- 29.1 g2
- Wireless
- Zigbee, Home Automation profile, end device2
- Radio
- -92 dBm sensitivity, +4 dBm typical output power2
- Firmware updates
- Over the air (Zigbee OTA cluster)3
Where it is used
VOC, temperature and humidity in offices, meeting rooms and classrooms, where a battery unit avoids new cabling.
Indoor environmental monitoringShowing when rooms need more ventilation, next to the energy used by the air handling plant.
HVAC energy monitoring for commercial buildingsHumidity in stores and archives where valuable items are kept, within its 0 to 50 °C range.
Interface
On the Zigbee network it joins as a sleepy end device.3
Readings and settings, with units and ranges where Develco publishes them.
| Reading | Unit | Range or values | Access |
|---|---|---|---|
| Measurements 4 | |||
| VOC | µg/m³ | - | Read only |
| Air quality | - | excellentgoodmoderatepoorunhealthyout_of_rangeunknown |
Read only |
| Temperature | °C | - | Read only |
| Humidity | % | - | Read only |
| Diagnostics 3 | |||
| Battery | % | 0 to 100 % | Read only |
| Voltage | mV | - | Read only |
| Battery low | - | Binary state | Read only |
VOC comes from a manufacturer-specific cluster (0xFC03, manufacturer code 0x1015) on endpoint 38, not a standard Zigbee measurement cluster. Temperature and humidity use the standard clusters on the same endpoint.3
The sensor measures VOC in ppb. Its Zigbee definition converts that to µg/m³ by multiplying by 4.5, the factor Sensirion gives for its reference TVOC mixture, and derives the air quality level from the ppb value using Develco’s five-level table.36
Battery voltage is reported in steps of 100 mV. The Zigbee definition maps 2.5 V to 0 % and 3.0 V to 100 %.35
The sensor checks in with its parent every 15 minutes. After five missed replies, up to 1 hour 15 minutes, it starts searching for the network again.3
Setup
-
Open pairing in Edge
In Edge, open pairing on the Gateway’s Zigbee network before you power the sensor.
-
Insert the batteries
Fit two AA cells. A sensor that has never joined a network starts searching straight away, and its LED flashes once a second until it joins.3
-
Or reset a used sensor
If the sensor was on another network, press and hold the button. The LED steps through the button menu, one mode every 5 seconds; release it when it indicates factory reset. The sensor clears its network settings and searches again.3
-
Confirm the join
The LED stops flashing when the sensor has joined. Check that Edge identifies it as Develco AQSZB-110.3
-
Mount it and check a reading
Mount it indoors in a heated room. Compare the first temperature and humidity reports with a reference instrument placed beside it; with default settings a new report arrives at least every 10 minutes.3
Common questions
- Why is VOC shown in µg/m³ when the datasheet uses ppb?
- The sensor reports ppb. Its Zigbee definition converts the value to µg/m³ by multiplying by 4.5, which is the factor Sensirion uses for its reference TVOC mixture. The air quality level is worked out from the ppb value.36
- How often does it report?
- By default every 10 minutes when values are stable. A change of 0.1 °C, 3 % RH or 10 ppb VOC is reported sooner, but not more often than once a minute. A hub that supports reporting configuration can change these settings.23
- How long do the batteries last?
- frient rates two AA alkaline cells for 2 years when reporting every 5 minutes. Replace them at 2.5 V; the red LED also blinks twice every 60 seconds when the battery is low.23
- What do the VOC levels mean?
- Develco maps the reading to five levels: excellent below 65 ppb, good from 65 to 220 ppb, moderate from 220 to 660 ppb, poor from 660 to 2200 ppb and unhealthy from 2200 ppb. Poor calls for more ventilation and unhealthy for intense ventilation.3
Sources
- Air Quality Sensor (opens in a new tab)
- Air Quality Sensor technical specifications, version 1.0 (opens in a new tab) (PDF)
- Air Quality Sensor AQSZB-110 technical manual, revised 04.08.2020 (opens in a new tab) (PDF)
- Develco AQSZB-110 device documentation (opens in a new tab)
- Develco AQSZB-110 device definition (opens in a new tab)
- Develco VOC and air quality conversions (opens in a new tab)