Heiman HS2AQ-EM
Air quality monitor
A Zigbee indoor air quality monitor with an OLED display. It measures PM2.5 from 1 to 999 µg/m³ and formaldehyde from 0.01 to 1.00 mg/m³, also reports PM10, total VOC, an air quality index, temperature and humidity, and runs from 5 V USB with a lithium backup battery.
Also sold asHS2AQ Smart Air Quality Monitor
- Zigbee
Air quality monitor
Compatibility
Compatible with EpiSensor Edge over Zigbee.
Pair it with the Zigbee radio on an EpiSensor Gateway. Edge reads it locally on the Gateway.
Edge reads 9 values from it, listed under Interface.
Connect it with
-
Gateway ZGW-20From €899 ex VAT Configure Gateway
Specifications
The HS2AQ-EM is the Zigbee identifier of Heiman’s HS2AQ Smart Air Quality Monitor, a round unit 96 mm across and 38 mm high that stands on a desk or mounts on a wall. It samples air by diffusion and shows its readings on an OLED display. A buzzer and a three-colour LED flag the air: green for clean, purple for light pollution and red for heavy pollution. Heiman specifies PM2.5 from 1 to 999 µg/m³ and formaldehyde from 0.01 to 1.00 mg/m³.1
- Power
- DC supply. 5 V DC at 1 A through a Micro USB socket, from a mains adapter (100 to 240 V AC in). A lithium battery inside backs it up.1
- PM2.5 range
- 1 to 999 µg/m³1
- Formaldehyde range
- 0.01 to 1.00 mg/m³1
- Also reported
- PM10 and total VOC in µg/m³, air quality index2
- Temperature error
- ±3 °C1
- Humidity error
- ±10 % RH1
- Sampling
- Diffusion1
- Display and alarm
- OLED display, buzzer, and an LED that shows green for clean air, purple for light pollution and red for heavy pollution1
- Operating conditions
- 0 to 40 °C, 15 to 90 % RH, non-condensing1
- Storage
- 0 to 50 °C, below 90 % RH1
- Radio range
- Up to 100 m; the real distance depends on the surroundings1
- Mounting
- On a desk, plugged in, or on a wall1
- Dimensions
- Ø96 mm, 38 mm high1
- Reporting
- At least hourly, and on each change of one unit3
Where it is used
Particulate, formaldehyde and VOC levels in offices, classrooms and newly fitted-out rooms.
Indoor environmental monitoringAir quality alongside HVAC energy data when ventilation settings change.
HVAC energy monitoring for commercial buildings
Interface
Readings and settings, with units and ranges where Heiman publishes them.123
| Reading | Unit | Range or values | Access |
|---|---|---|---|
| Measurements 7 | |||
| PM2.5Fine particulates. Standard Zigbee PM2.5 measurement cluster. | µg/m³ | 1 to 999 µg/m³ | Read only |
| PM10Coarse particulates. Heiman-specific cluster. | µg/m³ | - | Read only |
| FormaldehydeStandard Zigbee formaldehyde cluster; the raw value is divided by 1000. | mg/m³ | 0.01 to 1 mg/m³ | Read only |
| Total VOCHeiman-specific cluster. | µg/m³ | - | Read only |
| Air quality indexA unitless index from the Heiman-specific cluster. | - | - | Read only |
| TemperatureAccuracy ±3 °C. | °C | - | Read only |
| Relative humidityAccuracy ±10 % RH. | % | - | Read only |
| Diagnostics 2 | |||
| BatteryBackup battery level. The first report can take up to 24 hours. | % | 0 to 100 % | Read only |
| Battery stateWhether the backup battery is charging. | - | not_chargingchargingcharged |
Read only |
The Zigbee definition matches units that identify themselves as HS2AQ-EM or HS2AQ-EM-3.0. Units that report HS2AQ-EF-3.0 use a separate definition.3
Heiman’s current specification table names the Zigbee model HS2AQ-EFA, beside a Wi-Fi model (WS2AQ-A) and a HarmonyOS model (WS2AQ-H) with the same figures. Check the model the monitor reports when it joins.1
Setup
-
Power it
Plug the monitor into a 5 V, 1 A Micro USB supply. The lithium battery is a backup, so keep it on USB in normal use.1
-
Open pairing in Edge
In Edge, open pairing on the Gateway’s Zigbee network and bring the monitor close to the Gateway.
-
Confirm the join
Check that Edge identifies it as Heiman HS2AQ-EM and that PM2.5, formaldehyde and VOC readings arrive.2
-
Allow for the first battery report
The battery level can take up to 24 hours to appear after pairing. The air readings report hourly at the latest.2
Sources
- Environmental monitoring series: HS2AQ Smart Air Quality Monitor specifications (Chinese) (opens in a new tab)
- Heiman HS2AQ-EM device documentation (opens in a new tab)
- Heiman HS2AQ-EM device definition (opens in a new tab)
Further reading
Product names and trademarks belong to their owners. Publication does not imply endorsement or a commercial relationship.






