Develco FLSZB-110
Water leak detector
A battery-powered Zigbee water leak detector with an 85 dB siren and a built-in temperature sensor, sold as the frient Water Leak Detector. One CR123A cell lasts up to five years at a five-minute reporting interval.
Also sold asfrient Water Leak Detector
- Zigbee
Water leak detector
Compatibility
Compatible with EpiSensor Edge over Zigbee.
Pair it with the Zigbee radio on an EpiSensor Gateway. Edge reads it locally on the Gateway.
Edge reads 6 values from it, listed under Interface.
Connect it with
-
Gateway ZGW-20From €899 ex VAT Configure Gateway
Specifications
The FLSZB-110 is a round detector, 60 mm across and 37 mm high, that sits on the floor where water collects. It is sold as the frient Water Leak Detector, and its maker, Develco Products, now trades as Onics. When it detects water, even a few drops, it sounds an 85 dB siren and reports the leak over Zigbee at once. The siren keeps sounding until the water is gone or the battery runs out.12
- Power
- Battery. One CR123A cell, replaceable and fitted at the factory. Rated for five years reporting every five minutes.1
- Leak detection
- Detects small amounts of water; reports at once in alarm1
- Siren
- 85 dB at 3 m1
- Temperature range
- 0 to 50 °C1
- Temperature accuracy
- ±0.5 °C typical, ±2 °C maximum; 0.1 °C resolution1
- Working humidity
- Up to 95 % RH, non-condensing1
- Ingress protection
- IP201
- Wireless
- Zigbee 3.0 certified, Home Automation profile, end device1
- Radio range
- At least 100 m in open field1
- Dimensions
- Ø 60 × 37 mm1
- Weight
- 61.5 g1
- Probe accessory
- FLAPR-110, 900 mm cable1
- Approvals
- CE, FCC, IC, ISED, RED, RoHS1
Where it is used
Plant rooms and boiler houses, on the floor under boilers, calorifiers and pumps.
Boiler performance monitoringAlongside water metering: a meter residual shows water that is unaccounted for, and a detector on the floor shows where some of it has gone.
Water consumption monitoring for commercial buildingsComms rooms, under air-conditioning units and near pipework, with the temperature reading as a second check on the room.
Server room and rack temperature monitoring
Interface
Readings and settings, with units and ranges where Develco publishes them.
| Reading | Unit | Range or values | Access |
|---|---|---|---|
| Measurements 2 | |||
| Water leak | - | Binary state | Read only |
| Temperature | °C | - | Read only |
| Diagnostics 4 | |||
| Battery low | - | Binary state | Read only |
| Tamper | - | Binary state | Read only |
| Battery | % | 0 to 100 % | Read only |
| Voltage | mV | - | Read only |
It joins as a Zigbee end device, not a router, so it does not extend the mesh. Place it within range of the Gateway or a mains-powered router.1
The leak alarm is bit 0 of the IAS Zone status. The detector holds the alarm until the Gateway acknowledges it, then sends a cleared status if the water has gone, so the Gateway sees even a brief leak.2
By default, temperature reports at least every 600 seconds and at most every 60 seconds, on a change of 0.1 °C.2
The low-battery flag sets when the cell falls below 2.8 V. The red LED then blinks twice every 60 seconds.2
After 5 missed keep-alives in a row, at worst 1 hour 15 minutes, the detector starts scanning for its network again.2
Setup
-
Open pairing in Edge
In Edge, open pairing on the Gateway’s Zigbee network. The Gateway accepts new devices while pairing is open.
-
Power it up
Pull out the battery strip. A new detector starts searching for a network straight away, with its LED flashing once a second, and scans all channels for up to 15 minutes.2
-
Reset one that has been used before
Press and hold the button. The mode steps every 5 seconds, shown by short LED blinks. Release it at the factory reset mode: the detector clears its old network and starts searching again.2
-
Confirm the join
Check that Edge identifies it as Develco FLSZB-110 and shows a temperature. The detector reports its maker as frient A/S or Develco Products A/S, depending on the version.2
-
Test the alarm
Put a few drops of water under the detector. The siren sounds and Edge shows a water leak. Dry it and check that the leak state clears.3
Common questions
- Is the FLSZB-110 the same as the frient Water Leak Detector?
- Yes. FLSZB-110 is the model number of the frient Water Leak Detector. The device reports its maker as frient A/S or Develco Products A/S depending on the version, and Develco Products now trades as Onics.12
- Does it need a frient hub to work with Edge?
- No. It is Zigbee 3.0 certified and uses the standard Home Automation IAS Zone and temperature clusters, so it joins the Zigbee radio on an EpiSensor Gateway and Edge reads it there.12
- How quickly does it report a leak?
- At once. It reports immediately in alarm, and otherwise every 5 minutes. The siren sounds at the same time, so the leak is also heard on site.1
Sources
- Water Leak Detector technical specifications (opens in a new tab) (PDF)
- Flood Alarm FLSZB-110 technical manual (opens in a new tab) (PDF)
- Water Leak Detector (opens in a new tab)
- Develco FLSZB-110 device documentation (opens in a new tab)
- Develco FLSZB-110 Zigbee definition (opens in a new tab)
Further reading
Product names and trademarks belong to their owners. Publication does not imply endorsement or a commercial relationship.