Neptronic EFCB12TU2 / EFCB12TU4
HVAC fan coil controller
For a 240 Vac fan coil serving a two-pipe system, distinguish the water changeover sensor from the occupied-room reading. Request both on the handover schedule if the operator needs to explain why a room is heating or cooling.
Compatibility
Compatible with Edge over BACnet MS/TP or Modbus RTU
The EFCB serves the selected serial protocol. Edge reads BACnet points through a site BACnet router or collects Modbus RTU with a serial interface.
Confirm the installed protocol and the sensor selected in the fan coil configuration.
Connect it with
For a controller on a BACnet MS/TP trunk
- BACnet
- Edge
- Platforms
For an EFCB configured for Modbus RTU
- Modbus
- Edge
- Platforms
Models
| Models | Interface | Route into Edge |
|---|---|---|
| EFCB12TU2 | 240 Vac supply and 2 configurable relay outputs. | Record which relay functions the installer assigned on the equipment schedule. |
| EFCB12TU4 | 240 Vac supply and 4 configurable relay outputs. | Record which relay functions the installer assigned on the equipment schedule. |
Interface
Documented measurements and integration boundaries for EFCB12TU2 / EFCB12TU4.
- Analog Input 2 (ChangeOverTemp) reports the temperature of the wired changeover probe. Analog Value 1 (ControlTemp) is the configured temperature used to calculate demand.
- MSV 21 identifies the configured source for the control temperature, including the wall sensor, external probe or a network value.
Assessment
EFCB12TU2 and TU4 controllers with the documented room interface.
- InteroperabilityWell supported
- The EFCB guide identifies the objects and the supported BACnet properties.2
- AccuracySupported with conditions
- The object selected must represent the sensor at the required physical location.2
- SecurityNot yet assessed
- Site access controls depend on the building network.1
- ReliabilityNot yet assessed
- The installation specification describes operating conditions.1
- RuggednessSupported with conditions
- Neptronic specifies IP30 and a 0 to 50 °C operating range for the controller.1
- ScalabilitySupported with conditions
- Controllers share a serial trunk with assigned addresses and common network settings.1
- LifecycleSupported with conditions
- Match the supply voltage, relay count and wall-unit interface when specifying service stock.1
Setup
-
Record the controller and wall-unit codes, room served and selected serial protocol.
-
Where the changeover probe is fitted, read Present_Value and Units on AI 2.
Compare with a reference at the same pipe location during steady circulation.
-
Identify the measured location in the trend name.
Record the corresponding device and object identifiers for handover.
Sources
- EFCB with TFL2 or TDF, specification and installation instructions 251007 (opens in a new tab) (PDF)
- EFCB series BACnet communication guide 251006 (opens in a new tab) (PDF)