Neptronic EFCB10TU2 / EFCB10TU4
HVAC fan coil controller
For an existing 24 Vac fan coil, the TFL or TDF room unit can already supply the room temperature. Identify the wall unit and the EFCB in the equipment panel before quoting another sensor. The room unit uses a three-wire connection to the controller.
Compatibility
Compatible with Edge over BACnet MS/TP or Modbus RTU
The EFCB serves the selected serial protocol. Edge reads BACnet points through a site BACnet router or collects Modbus RTU with a serial interface.
Confirm the installed protocol and the sensor selected in the fan coil configuration.
Connect it with
For a controller on a BACnet MS/TP trunk
- BACnet
- Edge
- Platforms
For an EFCB configured for Modbus RTU
- Modbus
- Edge
- Platforms
Models
| Models | Interface | Route into Edge |
|---|---|---|
| EFCB10TU2 | 24 Vac supply and 2 configurable relay outputs. | Record which relay functions the installer assigned on the equipment schedule. |
| EFCB10TU4 | 24 Vac supply and 4 configurable relay outputs. | Record which relay functions the installer assigned on the equipment schedule. |
Interface
Documented measurements and integration boundaries for EFCB10TU2 / EFCB10TU4.
- Analog Input 7 (InternTemp) is the temperature measured by the sensor inside the TFL or TDF wall unit. Analog Value 1 is the temperature selected for control.
- MSV 21 identifies the configured source for the control temperature, including the wall sensor, external probe or a network value.
Assessment
EFCB10TU2 and TU4 controllers with the documented room interface.
- InteroperabilityWell supported
- The EFCB guide identifies the objects and the supported BACnet properties.2
- AccuracySupported with conditions
- The object selected must represent the sensor at the required physical location.2
- SecurityNot yet assessed
- Site access controls depend on the building network.1
- ReliabilityNot yet assessed
- The installation specification describes operating conditions.1
- RuggednessSupported with conditions
- Neptronic specifies IP30 and a 0 to 50 °C operating range for the controller.1
- ScalabilitySupported with conditions
- Controllers share a serial trunk with assigned addresses and common network settings.1
- LifecycleSupported with conditions
- Match the supply voltage, relay count and wall-unit interface when specifying service stock.1
Setup
-
Record the controller and wall-unit codes, room served and selected serial protocol.
-
Read Present_Value and Units on AI 7.
With the wall display set to internal temperature, compare the value and unit at the same time.
-
Identify the measured location in the trend name.
Record the corresponding device and object identifiers for handover.
Sources
- EFCB with TFL2 or TDF, specification and installation instructions 251007 (opens in a new tab) (PDF)
- EFCB series BACnet communication guide 251006 (opens in a new tab) (PDF)