Neptronic EFCB11TU2 / EFCB11TU4
HVAC fan coil controller
For a 120 Vac fan coil with a remote room probe, record where that probe is mounted and which input receives it. A return-air sensor and a wall sensor can produce different readings while both are working correctly.
Compatibility
Compatible with Edge over BACnet MS/TP or Modbus RTU
The EFCB serves the selected serial protocol. Edge reads BACnet points through a site BACnet router or collects Modbus RTU with a serial interface.
Confirm the installed protocol and the sensor selected in the fan coil configuration.
Connect it with
For a controller on a BACnet MS/TP trunk
- BACnet
- Edge
- Platforms
For an EFCB configured for Modbus RTU
- Modbus
- Edge
- Platforms
Models
| Models | Interface | Route into Edge |
|---|---|---|
| EFCB11TU2 | 120 Vac supply and 2 configurable relay outputs. | Record which relay functions the installer assigned on the equipment schedule. |
| EFCB11TU4 | 120 Vac supply and 4 configurable relay outputs. | Record which relay functions the installer assigned on the equipment schedule. |
Interface
Documented measurements and integration boundaries for EFCB11TU2 / EFCB11TU4.
- Analog Input 1 (ExternTemp) reports the external temperature probe on AI 1, or on AI 3 when configured for that purpose. AI 7 reports the sensor in the wall unit.
- MSV 21 identifies the configured source for the control temperature, including the wall sensor, external probe or a network value.
Assessment
EFCB11TU2 and TU4 controllers with the documented room interface.
- InteroperabilityWell supported
- The EFCB guide identifies the objects and the supported BACnet properties.2
- AccuracySupported with conditions
- The object selected must represent the sensor at the required physical location.2
- SecurityNot yet assessed
- Site access controls depend on the building network.1
- ReliabilityNot yet assessed
- The installation specification describes operating conditions.1
- RuggednessSupported with conditions
- Neptronic specifies IP30 and a 0 to 50 °C operating range for the controller.1
- ScalabilitySupported with conditions
- Controllers share a serial trunk with assigned addresses and common network settings.1
- LifecycleSupported with conditions
- Match the supply voltage, relay count and wall-unit interface when specifying service stock.1
Setup
-
Record the controller and wall-unit codes, room served and selected serial protocol.
-
Read Present_Value and Units on AI 1 after identifying the configured external probe.
Compare with a reference at that probe and record whether the value is in °C or °F.
-
Identify the measured location in the trend name.
Record the corresponding device and object identifiers for handover.
Sources
- EFCB with TFL2 or TDF, specification and installation instructions 251007 (opens in a new tab) (PDF)
- EFCB series BACnet communication guide 251006 (opens in a new tab) (PDF)
Further reading