Nous · MeteringD5Z

Zigbee smart energy meter with leakage and prepayment. Reports voltage, current, power and cumulative energy, and exposes a switched output and power-on behaviour with device status.

Nous D5Z device photograph
Photograph: Zigbee2MQTT (GPL-3.0)

Connection

EpiSensor Gateway with Zigbee radio running Edge

Documented Zigbee support describes the path Edge would use. It is not an EpiSensor compatibility claim for this model.

Readings and controls

What the pinned upstream definition exposes for this exact model. Units and ranges are only shown when that source states them.

Swipe to see every column

Download
Name Type Access Unit Range
switch switch
state binary Read and write
countdown numeric Read and write s 0–86400
power_on_behavior enum Read and write
inching composite Read and write
minutes numeric Read and write m 0–1440
seconds numeric Read and write s 0–59
status enum Read
power numeric Read W
current numeric Read A
voltage numeric Read V
energy numeric Read kWh
energy_produced numeric Read kWh
leakage_current numeric Read mA
device_temperature numeric Read °C
faults list Read
reclosing binary Read and write
reclosing_delay numeric Read and write s 1–99
reclosing_count numeric Read and write 0–30
prepayment binary Read and write
energy_balance numeric Read kWh
energy_balance_add numeric Read and write kWh 0–999999
energy_balance_reset enum Read and write
alarm_set_1 composite Read and write
leakage_current_alarm binary Read and write
leakage_current_threshold numeric Read and write mA 1–99
device_temperature_alarm binary Read and write
device_temperature_threshold numeric Read and write °C 10–85
over_current_threshold_time numeric Read and write s 0–999
alarm_set_2 composite Read and write
over_current_alarm binary Read and write
over_current_threshold numeric Read and write A 1–80
over_voltage_alarm binary Read and write
over_voltage_threshold numeric Read and write V 120–300
under_voltage_alarm binary Read and write
under_voltage_threshold numeric Read and write V 80–210
alarm_set_3 composite Read and write
lost_flow_alarm binary Read and write
lost_flow_threshold numeric Read and write A 1–100
lost_flow_threshold_time numeric Read and write s 0–999

Commissioning

A live socket is not a live measurement. Prove the decode, then keep the map.

  1. Pair the device on the Gateway Zigbee radio in Edge.

  2. Confirm the reported manufacturer and model match this page.

  3. Prove one known reading or control before enabling the rest of the points.

Sources

  1. Nous/D5Z (opens in a new tab) zigbee-herdsman-converters · v26.111.0

Built from the pinned Device Directory snapshot. Product names and trademarks belong to their respective owners; publication does not imply endorsement, a commercial relationship, or that EpiSensor has tested this model.