Continental Control Systems WattNode WNC-3Y-BN
Three-phase electricity meter
On a four-wire wye service, record both line-to-neutral and line-to-line voltages. A 230/400 V service and a 277/480 V service need different WattNode 3Y models. Include the installed CT primary rating and the number of feeders in the quote request.
Compatibility
Compatible with Edge over routed BACnet MS/TP
The BN meter presents its own BACnet Device instance on RS-485. Edge reads it from the building IP network through a BACnet router.
The revision 1.12a object table covers meter firmware 1.12. Check the BN suffix, firmware and installed CT rating when adding the first point.
Connect it with
For a BN meter on an existing MS/TP trunk
- BACnet
- Edge
- Platforms
Models
| Models | Interface | Route into Edge |
|---|---|---|
| WNC-3Y-208-BN | BACnet MS/TP. 120/208 V wye service with neutral. | Select this reference for the stated service and use the router serving the meter trunk. |
| WNC-3Y-400-BN | BACnet MS/TP. 230/400 V wye service with neutral. | Select this reference for the stated service and use the router serving the meter trunk. |
| WNC-3Y-480-BN | BACnet MS/TP. 277/480 V wye service with neutral. | Select this reference for the stated service and use the router serving the meter trunk. |
| WNC-3Y-600-BN | BACnet MS/TP. 347/600 V wye service with neutral. | Select this reference for the stated service and use the router serving the meter trunk. |
Interface
Documented measurements and integration boundaries for WattNode WNC-3Y-BN.
- Analog Input 1 (EnergyPosSumNR) reports non-resettable positive energy in kWh. Analog Input 2 (EnergyNegSumNR) tracks the negative direction separately.
- Analog Input 3 (PowerSum) reports watts. A kW demand trend and a kWh consumption total require separate points.
Assessment
Read-only monitoring of the identified BN variants on a routed MS/TP segment.
- InteroperabilityWell supported
- The BACnet manual publishes Analog Input identifiers, object names and units.1
- AccuracySupported with conditions
- Match the neutral reference and both service voltages. Separate import and export before preparing consumption totals.1
- SecurityNot yet assessed
- The meter includes non-resettable energy counters. Network access depends on the building controls design.1
- ReliabilitySupported with conditions
- The meter stores energy totals in non-volatile memory. Record collection gaps separately from changes in the counter.1
- RuggednessSupported with conditions
- The manual specifies indoor use. Include the location and enclosure when assessing an existing board.1
- ScalabilitySupported with conditions
- The manufacturer specifies up to 64 WattNode meters per RS-485 subnet. Inventory other devices on a shared trunk before choosing a collection interval.1
- LifecycleSupported with conditions
- Retain the full voltage and protocol suffix when ordering a replacement. The WNC series has distinct electrical service ratings.2
Setup
-
Ask the site engineer for the meter label, service configuration and installed CT rating.
The WattNode expects CTs with a nominal one-third-volt output.
-
Read Analog Input 1 at the start and end of a known interval.
Compare the increase in kWh with the same interval on an independent meter covering the same circuits. Record the timestamps and confirm that both meters use the same direction convention.
-
Save the Device instance, object type, instance, units and location with the site point list.