EpiSensor hardware

Sensors and interfaces for what you measure, one Gateway per site, and Edge running on it. Buy online or ask for a quote.

EpiSensor Gateway with a Wireless 3-Phase Electricity Monitor

Start with the Gateway

Then the sensors

Filter by what you measure. Not sure which you need? Build a system maps your site to devices.

EpiSensor Gateway and electricity monitor installed beside distribution boards

Built for real sites

Every EpiSensor device is built for plant rooms, switchboards and rooftops, and for estates that grow to thousands of devices. Why EpiSensor sets out what we design for, from mesh coverage to enclosures and documented measurement.

  • Zigbee 3.0 mesh: every mains-powered device extends coverage, about 1,000 m² each.
  • IP67 enclosures; the ZEM is double-insulated for mounting inside or outside a panel.
  • Up to 70,000 readings stored on the device through a radio outage.
  • AES-128 on the mesh, TLS 1.2 or later from the Gateway.

Sensors, one Gateway and Edge

Sensors report over Zigbee, and wired equipment over Modbus or BACnet, to one Gateway. Edge runs on it; platform connections are optional.

EpiSensor Edge
Platform
EpiSensor Gateway
Zigbee
Modbus
ZEM
ZDR
EpiSensor Zigbee devices
Third-party Zigbee devices
HVAC
Solar PV
Heat pumps
Battery storage
Meters
ZPC
BACnet
LoRaWAN
LoRaWAN devices
ZEM
Core
Retrofit friendly. No new wiring.
Kilometres of range, years on one battery.
Get rich data from legacy meters
Open APIs. Any platform.
Bring your own data SIM.

Documentation

The current datasheet for every product.

Datasheet

Wireless 3-Phase Electricity Monitor

Three-phase electricity monitor, Class 0.5S with its current sensors. Split-core CTs or Rogowski coils.

ZEM-65 · EPI-221 · Rev 00 · 958 KB (opens in a new tab) PDF, opens in a new tab
Datasheet

Demand Response Controller

Demand response controller with three-phase metering, grid-frequency monitoring, and a relay or Modbus set-point output.

ZDR-2X · EPI-211 · Rev 04 · 1.2 MB (opens in a new tab) PDF, opens in a new tab
Datasheet

Probe Temperature Sensor

Battery-powered temperature sensor with one or two external probes. IP67, probes IP68.

TES-2X · EPI-196 · Rev 00 · 608 KB (opens in a new tab) PDF, opens in a new tab
Datasheet

Pulse Counter

Pulse counter for water, gas, heat and electricity meters with a pulse output.

ZPC-2X · EPI-072 · Rev 00 · 525 KB (opens in a new tab) PDF, opens in a new tab
Datasheet

Analogue Signal Sensor

Analogue signal sensor for 4-20 mA and 0-10 V instruments.

ZIO-2X / ZVO-2X · EPI-231 · Rev 00 · 494 KB (opens in a new tab) PDF, opens in a new tab
Datasheet

M-Bus Interface

Reads one wired M-Bus meter and sends its energy, volume and temperature records to the Gateway over the wireless network.

ZHM-21 · 465 KB (opens in a new tab) PDF, opens in a new tab
Datasheet

Modbus Interface

Reads Modbus RTU devices over RS-485 and sends their registers to the Gateway.

ZMB-3X · EPI-195 · Rev 00 · 502 KB (opens in a new tab) PDF, opens in a new tab
Datasheet

Gateway

Runs Edge on Ubuntu Core. Zigbee, Bluetooth and LoRaWAN radios, dual Ethernet, optional Cellular and GNSS, up to 250 devices.

ZGW-20 · EPI-288 · Rev 00 · 2.2 MB (opens in a new tab) PDF, opens in a new tab