Sinopé · HVACTH1500ZB

Zigbee dual pole line volt thermostat. Exposes a heating setpoint and an operating mode.

Sinopé TH1500ZB device photograph
Photograph: Zigbee2MQTT (GPL-3.0)

Connection

EpiSensor Gateway with Zigbee radio running Edge

Documented Zigbee support describes the path Edge would use. It is not an EpiSensor compatibility claim for this model.

Readings and controls

What the pinned upstream definition exposes for this exact model. Units and ranges are only shown when that source states them.

Swipe to see every column

Download
Name Type Access Unit Range
climate climate
occupied_heating_setpoint numeric Read and write °C 5–30
unoccupied_heating_setpoint numeric Read and write °C 5–30
local_temperature numeric Read °C
system_mode enum Read and write
pi_heating_demand numeric Read % 0–100
running_state enum Read
thermostat_occupancy enum Read and write
second_display_mode enum Read and write
thermostat_outdoor_temperature numeric Read and write °C -99.5–99.5
outdoor_temperature_timeout numeric Read and write s 30–64800
enable_outdoor_temperature binary Read and write
temperature_display_mode enum Read and write
time_format enum Read and write
backlight_auto_dim enum Read and write
keypad_lockout enum Read and write

Commissioning

A live socket is not a live measurement. Prove the decode, then keep the map.

  1. Pair the device on the Gateway Zigbee radio in Edge.

  2. Confirm the reported manufacturer and model match this page.

  3. Prove one known reading or control before enabling the rest of the points.

Sources

  1. Sinopé/TH1500ZB (opens in a new tab) zigbee-herdsman-converters · v26.111.0

Built from the pinned Device Directory snapshot. Product names and trademarks belong to their respective owners; publication does not imply endorsement, a commercial relationship, or that EpiSensor has tested this model.