Sinopé · MeteringSW2500ZB

Zigbee smart light switch. Reports cumulative energy, and exposes a switched output and power-on behaviour.

Sinopé SW2500ZB device photograph
Photograph: Zigbee2MQTT (GPL-3.0)

Connection

EpiSensor Gateway with Zigbee radio running Edge

Documented Zigbee support describes the path Edge would use. It is not an EpiSensor compatibility claim for this model.

Readings and controls

What the pinned upstream definition exposes for this exact model. Units and ranges are only shown when that source states them.

Swipe to see every column

Download
Name Type Access Unit Range
timer_seconds numeric Read and write s 0–65535
led_intensity_on numeric Read and write % 0–100
led_intensity_off numeric Read and write % 0–100
led_color_on composite Write
r numeric Write
g numeric Write
b numeric Write
led_color_off composite Write
keypad_lockout enum Read and write
connected_load numeric Read and write W 0–1800
switch switch
state binary Read and write
power_on_behavior enum Read and write
energy numeric Read kWh
action enum Read

Commissioning

A live socket is not a live measurement. Prove the decode, then keep the map.

  1. Pair the device on the Gateway Zigbee radio in Edge.

  2. Confirm the reported manufacturer and model match this page.

  3. Prove one known reading or control before enabling the rest of the points.

Sources

  1. Sinopé/SW2500ZB (opens in a new tab) zigbee-herdsman-converters · v26.111.0

Built from the pinned Device Directory snapshot. Product names and trademarks belong to their respective owners; publication does not imply endorsement, a commercial relationship, or that EpiSensor has tested this model.