AVATTO · HVACZWT100

Zigbee Thermostat. Exposes a switched output and a child lock with field calibration.

AVATTO ZWT100 device photograph
Photograph: Zigbee2MQTT (GPL-3.0)

Connection

EpiSensor Gateway with Zigbee radio running Edge

Documented Zigbee support describes the path Edge would use. It is not an EpiSensor compatibility claim for this model.

Readings and controls

What the pinned upstream definition exposes for this exact model. Units and ranges are only shown when that source states them.

Swipe to see every column

Download
Name Type Access Unit Range
state binary Read and write
climate climate
current_heating_setpoint numeric Read and write °C 5–95
local_temperature numeric Read °C
local_temperature_calibration numeric Read and write °C -9.9–9.9
running_state enum Read
mode enum Read and write
child_lock binary Read and write
fault text Read
upper_temperature_limit numeric Read and write °C 15–95
frost_protection binary Read and write
work_days enum Read and write
sound binary Read and write
sensor_selection enum Read and write
temperature_variation numeric Read and write °C 0.5–10
sensor_temperature_limit numeric Read and write °C 25–95
weekly_schedule composite Read and write
workday_hour_1 numeric Read and write 0–23
workday_minute_1 numeric Read and write 0–59
workday_temp_1 numeric Read and write °C 5–95
workday_hour_2 numeric Read and write 0–23
workday_minute_2 numeric Read and write 0–59
workday_temp_2 numeric Read and write °C 5–95
workday_hour_3 numeric Read and write 0–23
workday_minute_3 numeric Read and write 0–59
workday_temp_3 numeric Read and write °C 5–95
workday_hour_4 numeric Read and write 0–23
workday_minute_4 numeric Read and write 0–59
workday_temp_4 numeric Read and write °C 5–95
workday_hour_5 numeric Read and write 0–23
workday_minute_5 numeric Read and write 0–59
workday_temp_5 numeric Read and write °C 5–95
workday_hour_6 numeric Read and write 0–23
workday_minute_6 numeric Read and write 0–59
workday_temp_6 numeric Read and write °C 5–95
weekend_hour_1 numeric Read and write 0–23
weekend_minute_1 numeric Read and write 0–59
weekend_temp_1 numeric Read and write °C 5–95
weekend_hour_2 numeric Read and write 0–23
weekend_minute_2 numeric Read and write 0–59
weekend_temp_2 numeric Read and write °C 5–95
backlight enum Read and write
direction_mode binary Read and write

Commissioning

A live socket is not a live measurement. Prove the decode, then keep the map.

  1. Pair the device on the Gateway Zigbee radio in Edge.

  2. Confirm the reported manufacturer and model match this page.

  3. Prove one known reading or control before enabling the rest of the points.

Sources

  1. AVATTO/ZWT100 (opens in a new tab) zigbee-herdsman-converters · v26.111.0

Built from the pinned Device Directory snapshot. Product names and trademarks belong to their respective owners; publication does not imply endorsement, a commercial relationship, or that EpiSensor has tested this model.