Beok · HVACBOT-R9V-ZB

Wall-mount thermostat. Exposes an operating mode and a child lock with battery level and field calibration.

Beok BOT-R9V-ZB device photograph
Photograph: Zigbee2MQTT (GPL-3.0)

Connection

EpiSensor Gateway with Zigbee radio running Edge

Documented Zigbee support describes the path Edge would use. It is not an EpiSensor compatibility claim for this model.

Readings and controls

What the pinned upstream definition exposes for this exact model. Units and ranges are only shown when that source states them.

Swipe to see every column

Download
Name Type Access Unit Range
climate climate
current_heating_setpoint numeric Read and write °C 5–60
local_temperature numeric Read °C
local_temperature_calibration numeric Read and write °C -9.9–9.9
system_mode enum Read and write
running_state enum Read
preset enum Read and write
child_lock binary Read and write
battery numeric Read % 0–100
valve_state enum Read
frost binary Read and write
deadzone_temperature numeric Read and write °C 0–5
min_temperature_limit numeric Read and write °C 5–30
max_temperature_limit numeric Read and write °C 15–60
eco_temperature numeric Read and write °C 5–30
schedule_monday text Read and write
schedule_tuesday text Read and write
schedule_wednesday text Read and write
schedule_thursday text Read and write
schedule_friday text Read and write
schedule_saturday text Read and write
schedule_sunday text Read and write

Commissioning

A live socket is not a live measurement. Prove the decode, then keep the map.

  1. Pair the device on the Gateway Zigbee radio in Edge.

  2. Confirm the reported manufacturer and model match this page.

  3. Prove one known reading or control before enabling the rest of the points.

Sources

  1. Beok/BOT-R9V-ZB (opens in a new tab) zigbee-herdsman-converters · v26.111.0