Shelly EM Gen4
A single-phase meter with two clamp-on current transformer channels up to 120 A and a 2 A dry contact for a contactor coil. Edge reads it through the Gateway’s Zigbee radio.
- Energy meters
Meters, sensors and controllers, and how each connects to Edge.
136 device pages · 37 manufacturers with device pages
469 devices
A single-phase meter with two clamp-on current transformer channels up to 120 A and a 2 A dry contact for a contactor coil. Edge reads it through the Gateway’s Zigbee radio.
A two-channel Zigbee energy meter with 80 A current clamps that reports voltage, frequency, and each channel's power, current, power factor and energy, with calibration factors you can trim from Edge. Edge reads it through the Gateway’s Zigbee radio.
A two-channel Zigbee energy meter with 80 A current clamps. Edge reads it through the Gateway’s Zigbee radio.
An 18 mm DIN-rail energy monitor with three split-core current transformers, for 3P+N supplies up to 120 A or 200 A per phase or three single-phase circuits. Edge reads it through the Gateway’s Zigbee radio.
A compact three-phase energy meter for 3P+N boards, up to 63 A per phase, that fits on the protective device or hangs on the cables instead of occupying DIN rail space. Edge reads it through the Gateway’s Zigbee radio.
Smart energy monitor for 3P+N system. Reports voltage, current, power, cumulative energy, frequency, power factor and exported energy.
Power meter. Reports voltage, current, power, cumulative energy and frequency with device status.
Energy meter. Reports power and cumulative energy, in charge-point, grid and solar roles. Connects over Modbus RTU (RS-485).
Energy meter. Reports power and cumulative energy, in charge-point, grid and solar roles. Connects over Modbus RTU (RS-485).
Energy meter. Reports power and cumulative energy, in charge-point, grid and solar roles. Connects over Modbus RTU (RS-485).
Energy meter. Reports power and cumulative energy, in charge-point, grid and solar roles. Connects over Modbus RTU (RS-485).
Power meter. Reports voltage, current, power, cumulative energy and harmonic distortion with device status.
Power meter. Reports voltage, current, power, cumulative energy, frequency and demand. Connects over Modbus RTU (RS-485) and Modbus TCP.
Power meter. Reports voltage, current, cumulative energy and frequency. Connects over Modbus RTU (RS-485) and Modbus TCP.
Power meter. Reports current and cumulative energy. Connects over Modbus RTU (RS-485) and Modbus TCP.
Power meter. Reports voltage, current, power, cumulative energy and frequency. Connects over Modbus RTU (RS-485) and Modbus TCP.
Energy meter. Reports power and cumulative energy, in charge-point, grid and solar roles. Connects over Modbus RTU (RS-485) and Modbus TCP.
Power meter. Reports voltage, cumulative energy and frequency with device status. Connects over Modbus RTU (RS-485) and Modbus TCP.
Power meter. Reports voltage, current, power, cumulative energy and frequency with device status. Connects over Modbus RTU (RS-485) and Modbus TCP.
Power meter. Reports voltage, cumulative energy and frequency with device status. Connects over Modbus RTU (RS-485) and Modbus TCP.
Power meter. Reports voltage, current, power, cumulative energy and frequency. Connects over Modbus RTU (RS-485) and Modbus TCP.
Energy meter. Reports power and cumulative energy, in a battery storage role. Connects over Modbus TCP.
Power meter. Reports voltage, current, power, frequency, power factor and demand. Connects over Modbus RTU (RS-485) and Modbus TCP.
Energy meter. Reports power and cumulative energy, in grid, solar and battery storage roles. Connects over Modbus RTU (RS-485) and Modbus TCP.
No devices match your filters
Try a broader model fragment, manufacturer or application.
Built from public Zigbee, LoRaWAN and Modbus device definitions and manufacturer documents. Exact manufacturer and model identities are joined; similar names are never assumed to be the same device.
A device that documents Zigbee 3.0, LoRaWAN or Modbus support connects to EpiSensor Edge through that protocol. A device page lists what the device reports, how to set it up and, where one exists, the Edge template for it.
Every page cites its sources. Zigbee device photographs come from the Zigbee2MQTT project and are credited under each photograph. We never run code from these sources, and register maps are for reading: never write to a meter from a map on this site.