Powernity · HVACPO-THCO-EAU

Thermostat radiator valve. Exposes a child lock with battery level and field calibration.

Powernity PO-THCO-EAU device photograph
Photograph: Zigbee2MQTT (GPL-3.0)

Connection

EpiSensor Gateway with Zigbee radio running Edge

Documented Zigbee support describes the path Edge would use. It is not an EpiSensor compatibility claim for this model.

Readings and controls

What the pinned upstream definition exposes for this exact model. Units and ranges are only shown when that source states them.

Swipe to see every column

Download
Name Type Access Unit Range
battery numeric Read % 0-100
child_lock binary Read and write - -
comfort_temperature numeric Read and write °C 0.5-29.5
eco_temperature numeric Read and write °C 0.5-29.5
holiday_temperature numeric Read and write °C 0.5-29.5
auto_temperature numeric Read and write °C 0.5-29.5
climate climate - - -
preset enum Read and write - -
local_temperature_calibration numeric Read and write °C -5.5-5.5
local_temperature numeric Read °C -
current_heating_setpoint numeric Read and write °C 0.5-29.5
boost_heating binary Read and write - -
boost_time numeric Read and write s 0-900
window_open binary Read - -
open_window_temperature numeric Read and write °C 5-25
open_window_time numeric Read and write minutes 0-60
error_status numeric Read - -

Commissioning

A live socket is not a live measurement. Prove the decode, then keep the map.

  1. Pair the device on the Gateway Zigbee radio in Edge.

  2. Confirm the reported manufacturer and model match this page.

  3. Prove one known reading or control before enabling the rest of the points.

Sources

  1. Powernity/PO-THCO-EAU (opens in a new tab) zigbee-herdsman-converters · v26.111.0

Built from the pinned Device Directory snapshot. Product names and trademarks belong to their respective owners; publication does not imply endorsement, a commercial relationship, or that EpiSensor has tested this model.