Plugwise · Environmental170-01

Emma Wired Pro / Emma Wireless. Reports temperature and humidity, and exposes a heating setpoint and an operating mode with battery level and field calibration.

Plugwise 170-01 device photograph
Photograph: Zigbee2MQTT (GPL-3.0)

Connection

EpiSensor Gateway with Zigbee radio running Edge

Documented Zigbee support describes the path Edge would use. It is not an EpiSensor compatibility claim for this model.

Readings and controls

What the pinned upstream definition exposes for this exact model. Units and ranges are only shown when that source states them.

Swipe to see every column

Download
Name Type Access Unit Range
application_fault_status numeric Read
oem_fault_code numeric Read 0–255
product_variant text Read
temperature numeric Read °C
climate climate
local_temperature numeric Read °C
local_temperature_calibration numeric Read and write °C -12.5–12.5
occupied_cooling_setpoint numeric Read and write °C 0–30
occupied_heating_setpoint numeric Read and write °C 5–30
system_mode enum Read and write
running_state enum Read
humidity numeric Read %
min_cool_setpoint_limit numeric Read and write °C 0–30
max_cool_setpoint_limit numeric Read and write °C 0–30
min_heat_setpoint_limit numeric Read and write °C 0–30
max_heat_setpoint_limit numeric Read and write °C 0–30
outdoor_temperature numeric Read °C
dhw_temperature numeric Read °C
return_water_temperature numeric Read °C
boiler_water_temperature numeric Read °C
external_heat_demand numeric Read and write °C 0–90
external_heat_demand_timeout numeric Read and write s 300–3600
max_dhw_setpoint numeric Read and write °C 0–100
max_boiler_setpoint numeric Read and write °C 0–100
boiler_setpoint numeric Read °C
battery numeric Read % 0–100
battery_type enum Read and write
keypad_lockout enum Read and write

Commissioning

A live socket is not a live measurement. Prove the decode, then keep the map.

  1. Pair the device on the Gateway Zigbee radio in Edge.

  2. Confirm the reported manufacturer and model match this page.

  3. Prove one known reading or control before enabling the rest of the points.

Sources

  1. Plugwise/170-01 (opens in a new tab) zigbee-herdsman-converters · v26.111.0

Built from the pinned Device Directory snapshot. Product names and trademarks belong to their respective owners; publication does not imply endorsement, a commercial relationship, or that EpiSensor has tested this model.