Moes · MeteringZHT-PT01-M-MS

Smart thermostat for pilot wire heating radiator. Exposes a switched output, an operating mode and a child lock with field calibration.

Moes ZHT-PT01-M-MS device photograph
Photograph: Zigbee2MQTT (GPL-3.0)

Connection

EpiSensor Gateway with Zigbee radio running Edge

Documented Zigbee support describes the path Edge would use. It is not an EpiSensor compatibility claim for this model.

Readings and controls

What the pinned upstream definition exposes for this exact model. Units and ranges are only shown when that source states them.

Swipe to see every column

Download
Name Type Access Unit Range
climate climate
current_heating_setpoint numeric Read and write °C 5–30
local_temperature numeric Read °C
preset enum Read and write
system_mode enum Read
local_temperature_calibration numeric Read and write °C -10–10
mode enum Read and write
window_open binary Read
fault binary Read
switch switch
window_detection binary Read and write
child_lock binary Read and write
temp_unit_convert enum Read and write
lower_temp numeric Read and write °C 5–30
upper_temp numeric Read and write °C 5–30
electricity_statistics numeric Read kWh
boost_duration numeric Read and write min 0–120
elec_statistics_day numeric Read
elec_statistics_month numeric Read
elec_statistics_year numeric Read
window_keep_time numeric Read and write min 0–120
fault_alarm enum Read
running_mode enum Read

Commissioning

A live socket is not a live measurement. Prove the decode, then keep the map.

  1. Pair the device on the Gateway Zigbee radio in Edge.

  2. Confirm the reported manufacturer and model match this page.

  3. Prove one known reading or control before enabling the rest of the points.

Sources

  1. Moes/ZHT-PT01-M-MS (opens in a new tab) zigbee-herdsman-converters · v26.111.0

Built from the pinned Device Directory snapshot. Product names and trademarks belong to their respective owners; publication does not imply endorsement, a commercial relationship, or that EpiSensor has tested this model.