Purpose-built hardware for real sites

Wireless sensing, energy metering, environmental monitoring and retrofit-ready devices designed for reliable deployment in the field.

EpiSensor ZEM wireless three-phase electricity monitor

Hardware for your site

Measure electricity and temperature, collect readings from existing meters, and connect industrial equipment. Choose the family for your application, then use its datasheet and configuration options to specify your installation.

Not sure which family your site needs? Answer a few questions instead

  1. ZEM

    Measure electricity where it is used.

    Monitor three-phase circuits with pre-calibrated current sensors. Bring electrical measurements from distribution boards and equipment onto the wireless site network.

    Measurement
    Three-phase electricity metering
    Current sensors
    Split-core CTs and flexible Rogowski coils
    Communications
    Zigbee wireless mesh
  2. ZDR

    Measure demand. Respond locally.

    Combine three-phase metering with local control for demand-response projects. Choose the controller and current sensors to suit the response service and installation.

    Measurement
    Three-phase electricity metering
    Control
    Relay switching; capabilities depend on configuration
    Communications
    Zigbee wireless mesh
  3. TES

    Temperature data from the places that matter.

    Monitor pipes, equipment and storage conditions with battery-powered wireless probes. Choose the probe style, cable length and number of channels for the installation.

    Sensing
    Single or dual external temperature probes
    Probe options
    Waterproof, pipe and general-purpose steel
    Power
    Replaceable battery
  4. ZPC

    Bring existing meters into your network.

    Collect pulse outputs from water, gas, heat and electricity meters. Send readings wirelessly to the Gateway without replacing the meter.

    Input
    Meter pulse outputs
    Channels
    Single or dual channel
  5. ZIO/ZVO

    Connect the instruments you already use.

    Bring analogue measurements from flow, pressure and other industrial transducers onto the wireless network. Choose current-loop or voltage inputs to match the instrument.

    Current input
    4–20 mA transducers
    Voltage input
    0–10 V transducers
    Channels
    Single or dual channel
  6. ZHM

    Read an M-Bus meter wirelessly.

    Connect one wired M-Bus meter to the EpiSensor wireless network. Collect utility readings through the Gateway, with an integrated relay for suitable valve-control applications.

    Meter connection
    One M-Bus meter per interface
    Valve relay
    1 A at 250 V AC, resistive load
    Enclosure
    IP67
  7. ZMB

    Connect serial equipment to the wireless network.

    Read and write Modbus RTU equipment through a local wireless interface. Integrate existing meters and controllers without running a data cable back to the Gateway.

    Protocol
    Modbus RTU
    Interface
    Serial connection to the equipment
    Power
    Integrated mains supply
  8. ZGW-20

    One place to connect, understand and act.

    Run EpiSensor Edge on site. Connect wireless sensors and supported wired equipment, work with their data, and configure local automation and onward integrations.

    Software
    EpiSensor Edge
    Connectivity
    Wireless and wired options
    Deployment
    Configure the hardware for your site
EpiSensor Gateway and electricity monitor installed beside distribution boards

Built for real sites.

A Gateway and a ZEM installed beside distribution boards. Choose sensors and interfaces for the measurements, environment and communications at your site. Their datasheets specify the installation requirements.

Wireless mesh
Zigbee connects wireless devices to the Gateway. Range depends on the building and installation.
Enclosures
Check each product’s protection rating, mounting and operating conditions for its location.
Local logging
On-device storage varies by product. Retention depends on the readings enabled and reporting interval.
Encrypted connections
AES-128 protects the Zigbee network; TLS protects supported connections to external services.

Complete the system

Sensors report to a Gateway. The Gateway runs Edge.

Every device on this page is one layer of a three-layer system. Choose the sensors for the site, add one Gateway, and Edge gives you the data, automation and integrations locally.

  1. 1

    Sensors and controllers

    The ranges above measure electricity, environment and signals, or interface to the meters and equipment already on site, and send readings over the wireless mesh.

    Back to the ranges
  2. 2 EpiSensor ZGW-20 Gateway

    Gateway

    ZGW-20 supports up to 250 devices, depending on the sensors and reporting load. Wireless radios, cellular and other connections depend on the selected hardware and installed integrations.

    Explore the Gateway
  3. 3 The Edge Data view, charting a plant's total active power over twenty-four hours.

    Edge

    Edge runs dashboards, data and automation locally on the Gateway. Connect external platforms when needed; remote access, notifications and exports need their network connection.

    Explore Edge

Datasheets and guides

Current technical documents from the shared library. Product detail pages carry the exact model and variant context.

ZEM-63 Electricity Monitor - first page preview EPI-221-00
Datasheet

ZEM-63 Electricity Monitor

Wireless three-phase electricity monitor. Class 0.5S measurement, split-core or Rogowski current sensors. Covers the ZEM-63; the ZEM-65 shares this specification.

EPI-221-00 · 960 KB
ZDR-2X Demand Response Controller - first page preview EPI-211-04
Datasheet

ZDR-2X Demand Response Controller

Wireless demand response controller with relay outputs and electricity metering.

EPI-211-04 · 1.2 MB
TES-2X Probe Temperature Sensor - first page preview EPI-196-00
Datasheet

TES-2X Probe Temperature Sensor

Wireless temperature sensor with external probe input. Battery-powered, IP67 rated.

EPI-196-00 · 610 KB
ZPC-2X Pulse Counter - first page preview EPI-072-00
Datasheet

ZPC-2X Pulse Counter

Wireless pulse/digital signal sensor. Count pulses from gas, water, or electricity meters.

EPI-072-00 · 526 KB
ZIO-2X Analogue Signal Sensor - first page preview EPI-231-00
Datasheet

ZIO-2X Analogue Signal Sensor

Wireless 4-20mA analogue signal sensor. Connect any 4-20mA device to Zigbee mesh.

EPI-231-00 · 496 KB
ZHM-21 Wireless M-Bus Interface - first page preview EPI-066-00
Datasheet

ZHM-21 Wireless M-Bus Interface

Reads one wired M-Bus meter and sends its energy, volume and temperature records to the Gateway over the wireless network.

EPI-066-00 · 467 KB
ZMB-3X Modbus Interface - first page preview EPI-195-00
Datasheet

ZMB-3X Modbus Interface

Wireless Modbus RTU bridge over RS-485. Connect Modbus devices to the Zigbee mesh network.

EPI-195-00 · 503 KB
ZGW-20 Gateway - first page preview EPI-288-00
Datasheet

ZGW-20 Gateway

Second-generation IoT gateway. Quad-core ARM, Ubuntu Core, Zigbee/Bluetooth/LoRaWAN, dual Ethernet, 3G/4G/5G cellular, GPS/GNSS, 250 devices.

EPI-288-00 · 2.2 MB
ZGW-10 Quick Start Guide (legacy) - first page preview EPI-264-00
User guide

ZGW-10 Quick Start Guide (legacy)

Setting up the discontinued ZGW-10 Gateway. For the ZGW-20, see the Gateway page.

EPI-264-00 · 165 KB

Know the range you need? Start the deployment.

Tell us about the sites and what you need to measure, and we will size the sensors, Gateway and Edge for you.

Contact us