Heat Decor · HVACHD-T1000

Floor thermostat. Exposes an operating mode and a child lock with field calibration.

Heat Decor HD-T1000 device photograph
Photograph: Zigbee2MQTT (GPL-3.0)

Connection

EpiSensor Gateway with Zigbee radio running Edge

Documented Zigbee support describes the path Edge would use. It is not an EpiSensor compatibility claim for this model.

Readings and controls

What the pinned upstream definition exposes for this exact model. Units and ranges are only shown when that source states them.

Swipe to see every column

Download
Name Type Access Unit Range
climate climate - - -
system_mode enum Read and write - -
running_state enum Read - -
local_temperature numeric Read °C -
local_temperature_calibration numeric Read and write °C -9-9
current_heating_setpoint numeric Read and write °C 5-35
work_mode enum Read and write - -
child_lock binary Read and write - -
frost_protection binary Read and write - -
window_detection binary Read and write - -
max_air_temperature numeric Read and write °C 35-95
max_floor_temperature numeric Read and write °C 5-60
deadzone_temperature numeric Read and write °C 0.5-5
window_detection_time numeric Read and write min 2-30
window_detection_temperature numeric Read and write °C 2-4
window_detection_recovery_time numeric Read and write min 10-60

Commissioning

A live socket is not a live measurement. Prove the decode, then keep the map.

  1. Pair the device on the Gateway Zigbee radio in Edge.

  2. Confirm the reported manufacturer and model match this page.

  3. Prove one known reading or control before enabling the rest of the points.

Sources

  1. Heat Decor/HD-T1000 (opens in a new tab) zigbee-herdsman-converters · v26.111.0

Built from the pinned Device Directory snapshot. Product names and trademarks belong to their respective owners; publication does not imply endorsement, a commercial relationship, or that EpiSensor has tested this model.