Excellux · EnvironmentalZS-300TF

Soil fertility sensor. Reports temperature, humidity, light level and soil moisture with battery level and field calibration.

Excellux ZS-300TF device photograph
Photograph: Zigbee2MQTT (GPL-3.0)

Connection

EpiSensor Gateway with Zigbee radio running Edge

Documented Zigbee support describes the path Edge would use. It is not an EpiSensor compatibility claim for this model.

Readings and controls

What the pinned upstream definition exposes for this exact model. Units and ranges are only shown when that source states them.

Swipe to see every column

Download
Name Type Access Unit Range
water_warning enum Read - -
soil_fertility_warning enum Read - -
battery numeric Read % 1-100
soil_moisture numeric Read % -
soil_fertility numeric Read μS/cm 0-5000
temperature numeric Read °C -
humidity numeric Read % -
illuminance numeric Read lx -
report_period numeric Read and write S 5-1200
soil_calibration numeric Read and write % -30-30
humidity_calibration numeric Read and write % -30-30
illuminance_calibration numeric Read and write lux -15-1000
temperature_calibration numeric Read and write °C -2-2
soil_warning numeric Read and write % 0-100
soil_fertility_calibration numeric Read and write μS/cm -1000-1000
soil_fertility_set_v0 numeric Read and write μS/cm 0-5000
soil_fertility_set_v1 numeric Read and write μS/cm 0-5000

Commissioning

A live socket is not a live measurement. Prove the decode, then keep the map.

  1. Pair the device on the Gateway Zigbee radio in Edge.

  2. Confirm the reported manufacturer and model match this page.

  3. Prove one known reading or control before enabling the rest of the points.

Sources

  1. Excellux/ZS-300TF (opens in a new tab) zigbee-herdsman-converters · v26.111.0

Built from the pinned Device Directory snapshot. Product names and trademarks belong to their respective owners; publication does not imply endorsement, a commercial relationship, or that EpiSensor has tested this model.