ONOKOM · ControlDK-1-ZB-S

Adapter for household Daikin systems. Exposes a switched output and an operating mode.

ONOKOM DK-1-ZB-S device photograph
Photograph: Zigbee2MQTT (GPL-3.0)

Connection

EpiSensor Gateway with Zigbee radio running Edge

Documented Zigbee support describes the path Edge would use. It is not an EpiSensor compatibility claim for this model.

Readings and controls

What the pinned upstream definition exposes for this exact model. Units and ranges are only shown when that source states them.

Swipe to see every column

Download
Name Type Access Unit Range
ac_connected enum Read
switch switch
state binary Read and write
current_temperature numeric Read °C
target_temperature numeric Read and write °C 16–32
system_mode enum Read and write
mode enum Read and write
outdoor_air_temperature numeric Read °C
zb_fan_speed numeric Read and write 1–5
vertical_vanes numeric Read and write 0–1
horizontal_vanes numeric Read and write 0–1
fan_speed numeric Read and write 0–5
smart_fan_speed numeric Read and write 0–7
vanes_swing numeric Read and write 0–3
status_led enum Read and write
quiet_mode binary Read and write
eco_mode binary Read and write
turbo_mode binary Read and write
ionization binary Read and write
screen_light binary Read and write
screen_low_bright binary Read and write
target_fan_rpm numeric Read and write 0–200
current_fan_rpm numeric Read 0–200

Commissioning

A live socket is not a live measurement. Prove the decode, then keep the map.

  1. Pair the device on the Gateway Zigbee radio in Edge.

  2. Confirm the reported manufacturer and model match this page.

  3. Prove one known reading or control before enabling the rest of the points.

Sources

  1. ONOKOM/DK-1-ZB-S (opens in a new tab) zigbee-herdsman-converters · v26.111.0

Built from the pinned Device Directory snapshot. Product names and trademarks belong to their respective owners; publication does not imply endorsement, a commercial relationship, or that EpiSensor has tested this model.