SODA · EnvironmentalS8

S8 premium window handle. Reports temperature and humidity, and exposes valve position with battery level.

SODA S8 device photograph
Photograph: Zigbee2MQTT (GPL-3.0)

Connection

EpiSensor Gateway with Zigbee radio running Edge

Documented Zigbee support describes the path Edge would use. It is not an EpiSensor compatibility claim for this model.

Readings and controls

What the pinned upstream definition exposes for this exact model. Units and ranges are only shown when that source states them.

Swipe to see every column

Download
Name Type Access Unit Range
battery numeric Read % 0–100
battery_low binary Read
vacation binary Read and write
alarm enum Read
alarm_switch binary Read and write
handlesound binary Read and write
opening_mode enum Read
temperature numeric Read °C
humidity numeric Read %
keysound binary Read and write
sensitivity enum Read and write
position enum Read
button_left enum Read
button_right enum Read
duration numeric Read and write sec 0–300
update_frequency numeric Read and write min 0–700
calibrate enum Read and write

Commissioning

A live socket is not a live measurement. Prove the decode, then keep the map.

  1. Pair the device on the Gateway Zigbee radio in Edge.

  2. Confirm the reported manufacturer and model match this page.

  3. Prove one known reading or control before enabling the rest of the points.

Sources

  1. SODA/S8 (opens in a new tab) zigbee-herdsman-converters · v26.111.0

Built from the pinned Device Directory snapshot. Product names and trademarks belong to their respective owners; publication does not imply endorsement, a commercial relationship, or that EpiSensor has tested this model.