SONOFF · ControlZBMINIL2

Zigbee smart switch (no neutral). Exposes a switched output and power-on behaviour.

SONOFF ZBMINIL2 device photograph
Photograph: Zigbee2MQTT (GPL-3.0)

Connection

EpiSensor Gateway with Zigbee radio running Edge

Documented Zigbee support describes the path Edge would use. It is not an EpiSensor compatibility claim for this model.

Readings and controls

What the pinned upstream definition exposes for this exact model. Units and ranges are only shown when that source states them.

Swipe to see every column

Download
Name Type Access Unit Range
switch switch
state binary Read and write
power_on_behavior enum Read and write

Edge template

Import the JSON in Edge → Settings → Device Templates. It sets the point map only. The Gateway connection, unit address and export names stay yours.

ZigbeeRevision 1.0.0

SONOFF ZBMINIL2: safe Edge baseline

Portable Zigbee configuration for the exact ZBMINIL2 Edge registry profile. It leaves the relay off after power is restored; pairing, the current relay state and site-specific export identifiers are deliberately not imposed. After installation, choose a different restoration policy only when it is safe for the connected load.

Exact product
ZBMINIL2
Included
1 mapped point · 1 setting group
Reviewed
Download Edge template

Sign-in and approved Edge download access required.

What Edge creates from this Zigbee device

Edge recognises either registry identity shown below. What it creates for this model comes from the pinned Edge registry; the downloaded file adds only the 1 disclosed baseline setting.

Registry identitiesSONOFF/ZBMINIL2

Sensors 1

Swipe to see every column

Download
SensorEdge IDUnitReadingRegistry property
Relay Statewritable 6507 Binary state

Settings 1

Swipe to see every column

Download
SettingTypeAcceptsRegistry field
Power On Behavior Choice Off, On, Toggle, Previous exposes.power_on_behavior

Export enabled and the export identifier stay site-specific on every mapped sensor: the template leaves both to the site.

Commands 1

Swipe to see every column

Download
CommandApplies toSendsRegistry command
Switch 6507 Relay State Enabled = 0, Disabled = 1 set-sensor

Import into Edge

  1. Download the JSON template.
  2. In Edge, open Settings → Device Templates and choose Import.
  3. Apply it to the exact model, set the site connection and unit address, then prove one known value before enabling the rest.

Commissioning

A live socket is not a live measurement. Prove the decode, then keep the map.

  1. Pair the device on the Gateway Zigbee radio in Edge.

  2. Confirm the reported manufacturer and model match this page.

  3. Prove one known reading or control before enabling the rest of the points.

Sources

  1. SONOFF/ZBMINIL2 (opens in a new tab) zigbee-herdsman-converters · v26.111.0

Built from the pinned Device Directory snapshot. Product names and trademarks belong to their respective owners; publication does not imply endorsement, a commercial relationship, or that EpiSensor has tested this model.