Excellux · EnvironmentalEZ-500FL

Split-type sensor for detecting soil moisture, soil fertility, temperature and humidity. Reports temperature and humidity with battery level and field calibration.

Excellux EZ-500FL device photograph
Photograph: Zigbee2MQTT (GPL-3.0)

Connection

EpiSensor Gateway with Zigbee radio running Edge

Documented Zigbee support describes the path Edge would use. It is not an EpiSensor compatibility claim for this model.

Readings and controls

What the pinned upstream definition exposes for this exact model. Units and ranges are only shown when that source states them.

Swipe to see every column

Download
Name Type Access Unit Range
battery numeric Read % 0–100
probe_temperature_warning enum Read
temperature_warning enum Read
humidity_warning enum Read
fertility_warning enum Read
moisture_warning enum Read
probe_temperature numeric Read °C -40–120
moisture numeric Read % 0–100
temperature numeric Read °C
humidity numeric Read %
fertility numeric Read μS/cm 0–5000
fertility_calibration numeric Read and write 0.5–2
sampling_interval numeric Read and write s 5–1200
probe_temperature_calibration numeric Read and write °C -2–2
probe_temperature_v0_set numeric Read and write °C -40–125
probe_temperature_v1_set numeric Read and write °C -40–125
temperature_calibration numeric Read and write °C -2–2
temperature_v0_set numeric Read and write °C -40–85
temperature_v1_set numeric Read and write °C -40–85
humidity_calibration numeric Read and write % -10–10
humidity_v0_set numeric Read and write % 0–100
humidity_v1_set numeric Read and write % 0–100
fertility_v0_set numeric Read and write μS/cm 0–5000
fertility_v1_set numeric Read and write μS/cm 0–5000
moisture_calibration numeric Read and write 0.2–1.5
moisture_v0_set numeric Read and write % 0–100
moisture_v1_set numeric Read and write % 0–100

Commissioning

A live socket is not a live measurement. Prove the decode, then keep the map.

  1. Pair the device on the Gateway Zigbee radio in Edge.

  2. Confirm the reported manufacturer and model match this page.

  3. Prove one known reading or control before enabling the rest of the points.

Sources

  1. Excellux/EZ-500FL (opens in a new tab) zigbee-herdsman-converters · v26.111.0

Built from the pinned Device Directory snapshot. Product names and trademarks belong to their respective owners; publication does not imply endorsement, a commercial relationship, or that EpiSensor has tested this model.