LoRaWAN

Decentlab DL-BLG

The Decentlab DL-BLG is equipped with a black globe temperature sensor. It is suitable for use in workplace safety, heat stress measurement, WBGT calculation for heat stress and meteorology.

environmentalTemperatureVoltage ratioThermistor resistance /Ω/TemperatureBattery voltage

Edge routeLoRaWAN network server connected to Edge through a supported IP integration

LoRaWAN

Decentlab DL-ISF

The Decentlab DL-ISF is a sap flow sensor for LoRaWAN®. Suitable for applications such as plant physiology, plant water use, hydraulic redistribution, hydrology, and irrigation scheduling.

environmentalSap FlowSap flow /l⋅h⁻¹/Heat velocity outer /cm⋅h⁻¹/Heat velocity inner /cm⋅h⁻¹/Alpha outerAlpha innerBeta outer

Edge routeLoRaWAN network server connected to Edge through a supported IP integration

LoRaWAN

Decentlab DL-LP8P

The Decentlab DL-LP8P is a LoRaWAN® end device equipped with CO₂, temperature, humidity, and barometric pressure sensors. Suitable for applications such as goods and storage condition monitoring, indoor and outdoor air quality, building automation, energy-saving, and smart agriculture.

meteringenvironmentalCO2TemperatureInfraredHumidityBarometric PressureAir temperature

Edge routeLoRaWAN network server connected to Edge through a supported IP integration

Modbus

Eaton BladeUPS

Eaton BladeUPS is listed as a ups in the pinned Modbus Device Maps catalogue. The preview does not declare the physical transport, so it must be confirmed from the current manufacturer documentation.

currentfrequencypowerstatustemperaturevoltage

Edge routeEpiSensor Edge Modbus Client over the RTU/RS-485 or TCP interface documented for the installed device; when the preview does not declare a transport, confirm it from the manufacturer manual. Upstream prerequisite: Each record is a 6–12-signal, read-oriented preview rather than a complete register map. Confirm the manufacturer manual, address base, function code, data layout, scaling, byte and word order, interface and firmware before commissioning. Never write a register from preview data.