OY1210 CO2 meter
OY1210 CO2 meter measures temperature, humidity and carbon dioxide. Supports adaptive reporting functions to detect rapid changes in CO2 values.
LoRaWAN network server connected to Edge through a supported IP integration
Search source-backed Zigbee, LoRaWAN and Modbus devices, then follow the documented connection route into Edge.
View reviewed integration guides Candidate records are not product endorsements
Identity, source capabilities and the interface Edge needs.
Page 18 of 124
OY1210 CO2 meter measures temperature, humidity and carbon dioxide. Supports adaptive reporting functions to detect rapid changes in CO2 values.
LoRaWAN network server connected to Edge through a supported IP integration
OY1700 Air quality (PM) sensor is designed to measure PM10, PM2.5, PM1.0, temperature and humidity in indoor environments. The sensor is intended for indoor climate control and monitoring indoor air quality. It is optimized for reliable and secure operations.
LoRaWAN network server connected to Edge through a supported IP integration
Zigbee din rail smart dimmer
EpiSensor Gateway with Zigbee radio running Edge
3-channel power strip with total energy monitoring
EpiSensor Gateway with Zigbee radio running Edge
Zigbee smart energy meter with leakage and prepayment
EpiSensor Gateway with Zigbee radio running Edge
Topazio 1 gang switch with socket
EpiSensor Gateway with Zigbee radio running Edge
Topazio 2 gang switch with socket
EpiSensor Gateway with Zigbee radio running Edge
NZIF SET-4TM is listed as a power meter in the pinned Modbus Device Maps catalogue. The preview declares Modbus RTU over RS-485 and Modbus TCP.
EpiSensor Gateway with an RS-485 interface for Modbus RTU, or Edge over Ethernet/IP for Modbus TCP. Upstream prerequisite: Each record is a 6–12-signal, read-oriented preview rather than a complete register map. Confirm the manufacturer manual, address base, function code, data layout, scaling, byte and word order, interface and firmware before commissioning. Never write a register from preview data.
Obvius A90DC-12 is listed as a power meter in the pinned Modbus Device Maps catalogue. The preview declares Modbus RTU over RS-485 and Modbus TCP.
EpiSensor Gateway with an RS-485 interface for Modbus RTU, or Edge over Ethernet/IP for Modbus TCP. Upstream prerequisite: Each record is a 6–12-signal, read-oriented preview rather than a complete register map. Confirm the manufacturer manual, address base, function code, data layout, scaling, byte and word order, interface and firmware before commissioning. Never write a register from preview data.
Relax smart plug
EpiSensor Gateway with Zigbee radio running Edge
32A/63A power circuit breaker
EpiSensor Gateway with Zigbee radio running Edge
Zigbee smart switch with power metering
EpiSensor Gateway with Zigbee radio running Edge
Temperature sensor
EpiSensor Gateway with Zigbee radio running Edge
Smart plug
EpiSensor Gateway with Zigbee radio running Edge
Smart plug
EpiSensor Gateway with Zigbee radio running Edge
Smart plug
EpiSensor Gateway with Zigbee radio running Edge
Power link
EpiSensor Gateway with Zigbee radio running Edge
Spruce temperature and moisture sensor
EpiSensor Gateway with Zigbee radio running Edge
Plug power socket on/off with power consumption monitoring
EpiSensor Gateway with Zigbee radio running Edge
Battery powered retrofit valve
EpiSensor Gateway with Zigbee radio running Edge
Soil moisture and temperature sensor
EpiSensor Gateway with Zigbee radio running Edge
Water level and temperature sensor
EpiSensor Gateway with Zigbee radio running Edge
Temperature and Humidity sensor
EpiSensor Gateway with Zigbee radio running Edge
Battery powered garden valve
EpiSensor Gateway with Zigbee radio running Edge
An upstream definition establishes a documented device identity and protocol route. It is enough for discovery, but it is not an endorsement and does not imply a ready-made Edge configuration.
Reviewed guides are the indexable model pages. They add model boundaries, interface details, point mapping and commissioning checks.