LoRaWAN
Nordic Propeye

OY1210 CO2 meter

OY1210 CO2 meter measures temperature, humidity and carbon dioxide. Supports adaptive reporting functions to detect rapid changes in CO2 values.

TemperatureHumidityCO2
Edge route

LoRaWAN network server connected to Edge through a supported IP integration

LoRaWAN
Nordic Propeye

OY1700 Particles meter

OY1700 Air quality (PM) sensor is designed to measure PM10, PM2.5, PM1.0, temperature and humidity in indoor environments. The sensor is intended for indoor climate control and monitoring indoor air quality. It is optimized for reliable and secure operations.

TemperatureHumidityParticulate Matter
Edge route

LoRaWAN network server connected to Edge through a supported IP integration

Modbus
NZIF

SET-4TM

NZIF SET-4TM is listed as a power meter in the pinned Modbus Device Maps catalogue. The preview declares Modbus RTU over RS-485 and Modbus TCP.

energypowerstatustemperature
Edge route

EpiSensor Gateway with an RS-485 interface for Modbus RTU, or Edge over Ethernet/IP for Modbus TCP. Upstream prerequisite: Each record is a 6–12-signal, read-oriented preview rather than a complete register map. Confirm the manufacturer manual, address base, function code, data layout, scaling, byte and word order, interface and firmware before commissioning. Never write a register from preview data.

Modbus
Obvius

A90DC-12

Obvius A90DC-12 is listed as a power meter in the pinned Modbus Device Maps catalogue. The preview declares Modbus RTU over RS-485 and Modbus TCP.

currentpowertemperatureModbus RTU / RS-485
Edge route

EpiSensor Gateway with an RS-485 interface for Modbus RTU, or Edge over Ethernet/IP for Modbus TCP. Upstream prerequisite: Each record is a 6–12-signal, read-oriented preview rather than a complete register map. Confirm the manufacturer manual, address base, function code, data layout, scaling, byte and word order, interface and firmware before commissioning. Never write a register from preview data.

What a catalogue record means

An upstream definition establishes a documented device identity and protocol route. It is enough for discovery, but it is not an endorsement and does not imply a ready-made Edge configuration.

Reviewed guides are the indexable model pages. They add model boundaries, interface details, point mapping and commissioning checks.