Energy device catalogue

Search source-backed Zigbee, LoRaWAN and Modbus devices, then follow the documented connection route into Edge.

View reviewed integration guides Candidate records are not product endorsements

2958 matching devices

Identity, source capabilities and the interface Edge needs.

Page 14 of 124

Zigbee
HOBEIAN

ZG-303Z-z

Soil moisture sensor (pvvx/ZigbeeTLc)

batteryvoltageidentifytemperature
Edge route

EpiSensor Gateway with Zigbee radio running Edge

Modbus
Huawei

Sun2000

Huawei Sun2000 is listed as a solar inverter in the pinned Modbus Device Maps catalogue. The preview does not declare the physical transport, so it must be confirmed from the current manufacturer documentation.

currentpowerstatustemperature
Edge route

EpiSensor Edge Modbus Client over the RTU/RS-485 or TCP interface documented for the installed device; when the preview does not declare a transport, confirm it from the manufacturer manual. Upstream prerequisite: Each record is a 6–12-signal, read-oriented preview rather than a complete register map. Confirm the manufacturer manual, address base, function code, data layout, scaling, byte and word order, interface and firmware before commissioning. Never write a register from preview data.

Modbus
Huawei

Sun2000 -env

Huawei Sun2000 -env is listed as a solar inverter in the pinned Modbus Device Maps catalogue. The preview does not declare the physical transport, so it must be confirmed from the current manufacturer documentation.

currentpowerstatustemperature
Edge route

EpiSensor Edge Modbus Client over the RTU/RS-485 or TCP interface documented for the installed device; when the preview does not declare a transport, confirm it from the manufacturer manual. Upstream prerequisite: Each record is a 6–12-signal, read-oriented preview rather than a complete register map. Confirm the manufacturer manual, address base, function code, data layout, scaling, byte and word order, interface and firmware before commissioning. Never write a register from preview data.

Modbus
I-Real

WS0101

I-Real WS0101 is listed as a power meter in the pinned Modbus Device Maps catalogue. The preview declares Modbus RTU over RS-485 and Modbus TCP.

currentenergypowertemperature
Edge route

EpiSensor Gateway with an RS-485 interface for Modbus RTU, or Edge over Ethernet/IP for Modbus TCP. Upstream prerequisite: Each record is a 6–12-signal, read-oriented preview rather than a complete register map. Confirm the manufacturer manual, address base, function code, data layout, scaling, byte and word order, interface and firmware before commissioning. Never write a register from preview data.

What a catalogue record means

An upstream definition establishes a documented device identity and protocol route. It is enough for discovery, but it is not an endorsement and does not imply a ready-made Edge configuration.

Reviewed guides are the indexable model pages. They add model boundaries, interface details, point mapping and commissioning checks.